Changes in configuration switches
The table below is a summary of the differences between PHC10-3 PLUS and PHC10-2 configuration switch settings that allows you to
correctly configure your PHC10-3 PLUS when replacing a PHC10-2.
PHC10-2 switch
PHC10-3 PLUS switch
equivalent
Function
Up
Down
Communications
1
1#
Baud rate
2
2#
Baud rate
3
3#
Baud rate
4 (not used)
5 (not used)
6
4*#
Stop bit
2 stop bits
1 stop bit
7
5*#
CTS protocol
CTS on
CTS off
8
6*#
LF protocol
LF on
LF off
9
9#
Command set
Extended
Basic
10
10
Probe reseat time
Extended
Standard
Interface
11
7
PPOFF
PPOFF - active during
head index
PPOFF - inactive during
head index
12
8
HCU2 probe, DAMP and
probe reset buttons
Enabled
Disabled
13 (not used)
14 (not used)
15+16
12
Output configuration
PICS
DIN
17+18
11
Interface connection
PICS or 7-pin DIN
operation
5-pin DIN operation only
13
Probe wire isolation
Machine cable
Multiwire
* Operational only when basic command set selected (switch 9 down)
# Not required for USB operation default position = down
NOTE:
Switches 4,5,13 and 14 had no function in PHC10-2.
NOTE:
Download the USB driver package for PHC10-3 PLUS
.
PHC10-3 PLUS installation guide
www.renishaw.com
Issued 12 2021