background image

Operating elements

7

1

3

2

4

5

6

8

9

10

Front side

Rear side

Outdoor fountain 

Mains plug

3  Cable opening

4  Mains cable

Riser pipe

Connector plug

Socket

Pump

Cover

10 

LED unit

Operation

•  Place the outdoor fountain (1) on a flat, secure and horizontal surface. Place the 

pump (8) and the power supply (2) outside the fountain on a dry surface.

•  Guide the cable with the connector plug (6) and the riser pipe (5) from the inside of 

the fountain through the cable opening (3) on the side of the fountain. 

•  Connect the connector plug to the socket (7). Secure the connection using the union 

nut on the connector plug.

•  Connect the pump to the riser pipe and place the pump on the ground inside the 

fountain.

•  Plug the connector on the mains cable (4) into the connection socket on the power 

supply. Screw the union nut in place. 

Do 

not

 connect the mains plug to the mains socket. This will be done later.

• 

Pour clean, clear water through the water inlets on the top of the fountain. Observe 

the water level through the opening on the side. The water level markings for the 

minimum water level 

MIN

 and the maximum water level 

MAX

 are located inside 

the fountain. The water level must always be between the 

MIN

 and 

MAX

 markings.

•  Place the cover (9) on the cable opening on the side of the fountain. Pay attention to 

the holes on the cable opening and the cover. The hole on the cover is for feeding 

the cable. The cable must not be pinched! 

•  Place the mains plug into a suitable outdoor socket (IP44). The pump starts working 

immediately and the white LEDs turn on. The water is pumped upwards through the 

opening in the middle of the LED unit (10) and flows back into the fountain via the 

water inlets on the surface.

Ensure that the cable is placed in a 

drip loop. This prevents water from 

flowing  along  the  mains  cable  to 

the mains socket. This may lead to 

a fatal electric shock!

To the 

pump

Drip loop

•  Remove the mains plug from the mains socket after use. The pump stops immediately 

and the LEDs turn off.

Setting the flow volume

Disconnect  the  pump  from  the  power  supply.  You  can  set  the  desired  water  flow 

volume using the slide switch on the front on the pump. Move it towards "+" to increase 

the flow volume. Move it towards "-" to decrease the flow volume.

Troubleshooting

Problem

Suggested solution

The pump does not deliver any 

water or is noisier than usual.

There is not enough water in the container. 

Remove the power adapter from the mains 

socket. Fill the fountain with clear water to 

at least the 

MIN

 mark but not higher than the 

MAX

 mark. Plug the mains plug back into the 

mains socket.

The pump does not deliver enough 

water.

Increase the water flow volume (see "Setting 

the flow volume").

There is air in the pump.

Disconnect the power adapter from the mains 

and disconnect the pump. Pour water into the 

tube from above. Plug the pump back in and 

insert the mains plug into the mains socket.

Maintenance and cleaning

•  Never use aggressive detergents, rubbing alcohol or other chemical solutions, as 

these could damage the housing or even impair the functioning of the product.

• 

Always unplug the mains plug from the mains socket before cleaning.

•  Change the water every three days. If possible, use clear, purified water. 
•  Remove coarse dirt and clean the fountain. Use protective gloves to prevent injuries.
•  If  dirt  has  accumulated  in  the  pump  inlet,  disconnect  the  pump  from  the  mains. 

Remove the dirt and rinse the pump with clean, flowing water.

• 

Pay attention to the information in the 

Technical data

. Empty the water. Store the 

product in a frost-proof room as soon as the outdoor temperature drops to a level 

where there is a risk of frost.

Disposal

Electronic devices are recyclable waste and must not be disposed of in the 

household waste.
At the end of its service life, dispose of the product according to the 

relevant statutory regulations.

You thus fulfil your statutory obligations and contribute to the protection of 

the environment.

Technical data

a)  Outdoor fountain and pump

Operating voltage/current .................

12 V/AC, 50 Hz (pump)

Power consumption............................

max. 7 W (pump)

LED.........................................................

6 x LED (white), 0.125 W each

Colour temperature

.............................

6000 - 7000K

Protection type ....................................

IPX8

Protection class ..................................

III

Water volume ......................................

12.5 to 21.5 l

MIN

 water level marking. ..................

7 cm

MAX

 water level marking. .................

13 cm

Pump head ...........................................

max. 0.95 m

Water temperature .............................

+1 to +35 °C

Operating conditions ..........................

+1 to +35 °C, 0 - 90 % RH

Storage conditions..............................

+1 to +35 °C, 0 - 90 % RH

Mains cable length .............................

approx. 5 m

Dimensions (W x H x D)

......................

535 x 660 x 340 mm (outdoor fountain)

Weight ...................................................

approx. 9.4 kg (outdoor fountain with pump)

b)  Power adapter

Input voltage/current

..........................

230-240 V/AC, 50Hz, 70 mA

Power consumption............................

max. 11 W

Output voltage/current .......................

12 V/AC, 1 A

Protection type ....................................

IP44

Protection class ..................................

II

Weight ...................................................

610 g

This is a publication by Conrad Electronic SE, Klaus-Conrad-Str. 1, D-92240 Hirschau (www.conrad.com). 
All  rights  including  translation  reserved.  Reproduction  by  any  method,  e.g.  photocopy,  microfilming,  or  the  capture  in  electronic  data 

processing systems require the prior written approval by the editor. Reprinting, also in part, is prohibited. This publication represent the 

technical status at the time of printing.

© Copyright 2015 by Conrad Electronic SE. 

V1_0215_02-HK

Summary of Contents for 1300046

Page 1: ...s unterwiesen wurden und die daraus resultierenden Gefahren verstanden haben Reinigung und Benutzer Wartung dürfen nicht von Kindern durchgeführt werden es sei denn sie werden beaufsichtigt Kinder müssen beaufsichtigt werden damit sie nicht mit dem Gerät spielen Achtung LED Licht Nicht in den LED Lichtstrahl blicken Nicht direkt oder mit optischen Instrumenten betrachten Der Aufbau der Pumpe entsp...

Page 2: ...r in Richtung bewegt so wird die Fördermenge verringert Problembehebung Problem Lösungsvorschlag Pumpe fördert kein Wasser oder zeigt einen erhöhten Geräuschpegel Zu wenig Wasser im Behälter Netzteil aus der Steckdose ziehen Befüllen Sie den Brunnen mindestens bis zur Markierung MIN jedoch höchstens bis zur Markierung MAX mit klarem Wasser Netzteil wieder mit der Steckdose verbinden Pumpe fördert ...

Page 3: ...understand the hazards involved Cleaning and user maintenance shall not be made by children without supervision Children shall not play with the appliance Attention LED light Do not look directly into the LED light Do not look into the beam directly or with optical instruments The pump is built according to protection class III and IPX8 The mains plug must not get wet or damp When placing the foun...

Page 4: ...o at least the MIN mark but not higher than the MAX mark Plug the mains plug back into the mains socket The pump does not deliver enough water Increase the water flow volume see Setting the flow volume There is air in the pump Disconnect the power adapter from the mains and disconnect the pump Pour water into the tube from above Plug the pump back in and insert the mains plug into the mains socket...

Page 5: ... condition qu ils soient supervisés ou qu ils aient reçu des instructions quant à l utilisation en toute sécurité de l appareil et qu ils comprennent les dangers relatifs son utilisation Les enfants ne doivent pas être autorisés à nettoyer ou entretenir l appareil à moins d être supervisés Les enfants doivent rester sous surveillance pour garantir qu ils ne jouent pas avec l appareil Attention Pré...

Page 6: ... Si le régulateur coulissant est déplacé dans la direction le débit est réduit Dépannage rapide Problème Solution possible La pompe ne refoule pas d eau ou a un niveau acoustique élevé Pas assez d eau dans le réservoir Débranchez le bloc d alimentation de la prise Remplissez la fontaine au moins jusqu au repère MIN et au plus jusqu au repère MAX avec de l eau claire Rebranchez le bloc d alimentati...

Page 7: ...ke sensorische of mentale vaardigheden of een gebrek aan ervaring en of kennis worden gebruikt als zij onder toezicht staan of omtrent het veilige gebruik van het apparaat werden geïnstrueerd en de hieruit resulterende gevaren hebben begrepen Reiniging en onderhoud door de gebruiker mogen niet door kinderen worden uitgevoerd tenzij zij worden begeleid Kinderen moeten onder toezicht staan om ervoor...

Page 8: ...ng wordt geschoven wordt de pompcapaciteit verminderd Verhelpen van storingen Probleem Oplossingssuggestie Pomp levert geen water of heeft een verhoogd geluidsniveau Te weinig water in het reservoir Netvoedingadapter uit het stopcontact trekken Vul de fontein tenminste tot de markering MIN echter maximaal tot de markering MAX met schoon water Netvoedingadapter weer in het stopcontact steken Pomp l...

Reviews: