d) Handling, Operation

•  Use the product only in a temperate climate, never in a tropical climate.
•  Do not use the product if it is damaged. There is a risk of a life-threatening electric 

shock! 

•  If it can be assumed that safe operation is no longer possible, the device must be 

turned off and precautions are to be taken to ensure that it is not used unintention-

ally. Do not touch the product.
First switch off the mains voltage to all poles (switch off the connected circuit 

breaker or remove the fuse and then switch off the connected RCD). 
After this, arrange for a skilled electrician to check the product.

•  Safe operation can no longer be assumed if:

 - the product shows visible signs of damage
 - the product does not work at all or well (flickering light, leaking smoke or a smell 

of burning, the light flickers, audible cracking noises, discolouration to the prod-

uct or the adjacent surfaces.)

 - the product was stored under unfavourable conditions

Preparations for Installation

 

Please observe the chapter „Safety Instructions“!

•  Install the moisture-proof LED diffuser luminaire only on a stable surface. Use screws and 

plugs that are suitable for the surface. Use the moisture-proof LED diffuser luminaire only 

when it is permanently installed.

•  The moisture-proof LED diffuser luminaire must be set up and used out of the reach of 

children.

•  The moisture-proof LED diffuser luminaire must be protected on the sub-distribution board 

by a10/16 A fuse. An earth fault circuit interrupter must be installed before this (FI protective 

switch).

•  During installation, the moisture-proof LED diffuser luminaire must be disconnected from the 

power supply. It is not sufficient to just turn off the light switch!
Switch off all the poles of the mains cable by removing the corresponding fuse or switching off 

at the circuit breaker. Then, switch off the associated earth fault circuit interrupter (breaker). 

Secure it against an unauthorised re-start, e.g., with a danger sign. 

•  Check that the mains connection is free of current, i.e. with an appropriate tester. 

Installation and connection

 

Pay attention to the information in the chapter „Preparing for Installation“! 

•  First install the two holding brackets. Depending on the substrate, drill the holes (1) and 

use the dowels (2); the interval between the holes for two holding brackets must be ap-

prox. 97 cm. Then screw down the holding brackets with two screws (3).

 

When drilling mounting holes or screwing into place, ensure that no existing electri-

cal cable, gas or water pipes are damaged.

•  Remove the cover from the underside of the product, on the side of cable gland. Use a slot 

screwdriver for this purpose and pry open carefully the four clips of the cover (4). Then the 

cover can be easily removed (5).

•  Remove the outer insulation of the power supply cable for a length of about 3 cm. Remove 

the insulation of individual wires for a length of 6 mm.

•  Push connection cable through the cable gland and connect the mains supply line (brown 

wire = L/phase, blue wire = N/neutral) with corresponding screw terminals in the moisture-

proof LED diffuser luminaire (7).

 

The moisture-proof LED diffuser luminaire is designed according to protection class II. 

There is no need in a protective conductor. If your connection cable has a protective 

conductor, pinch off or fasten the yellow-green wire inside the moisture-proof LED 

diffuser luminaire to the free central terminal to fix it safely.

•  Now screw the cable gland (8) tight to fasten the power supply line correctly and thus ensure 

protection against penetrating humidity.

•  Replace the cover (9) so that all four corners click properly into place. 
•  Clip the moisture-proof LED diffuser luminaire to both holding brackets, so that the latter click 

properly into side openings.

•  Switch on the mains voltage and make sure that the moisture-proof LED diffuser luminaire 

is functioning.

 

If the moisture-proof LED diffuser luminaire is not lit up, switch off the mains voltage 

immediately from all poles (take out the fuse or switch off the automatic cut-out, 

switch off the earth fault circuit interrupter).

 

Thereafter, check the connections of the moisture-proof LED diffuser luminaire.

 

In case of doubt, contact a professional (e.g., an electrician)!

Maintenance and Cleaning

•  The product is maintenance-free. Repair or maintenance work must be carried out by a 

specialist. The LED bulb is permanently installed and cannot be replaced.

•  Before cleaning, turn off the mains voltage for the moisture-proof LED diffuser luminaire and 

let it cool down sufficiently.

•  You can use a clean, dry, soft cloth for cleaning. In case of heavier soiling, you can moisten 

the cloth with clean water.

•  Never direct water jets from a high-pressure cleaner or similar at the moisture-proof LED 

diffuser luminaire. 

•  Never use abrasive cleaning agents, cleaning alcohol or other chemical solutions, since 

these could damage the housing or even impair operation.

Disposal

  Electronic devices are recyclable material and do not belong in the household 

waste. Dispose of an unserviceable product in accordance with the relevant statu-

tory regulations.

Technical Data

Operating voltage ......................... 220 - 240 V/AC, 50/60 Hz
Power input  .................................. 24 W
Protection class ............................ II
Protection level ............................. IP65
Mounting location ......................... indoors/outdoors
Number of LEDs ........................... 132 (firmly mounted, not replaceable)
Dimmable .....................................  no
Light colour ................................... 4000 K (neutral white)
Luminous flux ............................... 2000 lm
Operating conditions  .................... Temperature -20 °C to +40 °C
Dimensions ................................... 1180 x 66 x 86 mm (L x W x H)
Weight .......................................... 1.2 kg

Summary of Contents for 1483723

Page 1: ...zw ein Si cherungsautomat max 16 A befinden Die Montage und der Anschluss darf nur dann erfolgen wenn die Zuleitungen allpolig von der Netzspannung getrennt sind Andernfalls besteht Lebensgefahr durch einen elektrischen Schlag Verbinden Sie das Produkt niemals gleich dann mit der Netzspannung wenn es von einem kalten Raum in einen warmen Raum gebracht wurde z B bei Trans port Das dabei entstehende...

Page 2: ...n von Montagelöchern bzw beim Festschrau ben keine vorhandenen Kabel oder Leitungen beschädigt werden Entfernen Sie die Abdeckung auf der Unterseite die sich an der Seite der Kabelverschrau bung befindet Verwenden Sie hierzu einen Schlitzschraubendreher und hebeln Sie die vier Clipse der Abdeckung vorsichtig auf 4 Anschließend lässt sich die Abdeckung leicht ab nehmen 5 Entfernen Sie die äußere Is...

Page 3: ... be an appropriately di mensioned fuse or circuit breaker max 16 A Perform installation and connection only when all supply lines are disconnected from the mains voltage Otherwise there is a risk of a life threatening electric shock Do not connect the product to the power supply immediately after it has been transferred from a cold room into a warm one e g during transport The conden sation that f...

Page 4: ...ews 3 When drilling mounting holes or screwing into place ensure that no existing electri cal cable gas or water pipes are damaged Remove the cover from the underside of the product on the side of cable gland Use a slot screwdriver for this purpose and pry open carefully the four clips of the cover 4 Then the cover can be easily removed 5 Remove the outer insulation of the power supply cable for a...

Page 5: ...coupe circuit automatique max 16 A Le montage et le raccordement ne doivent se faire que si les câbles d alimentation sont coupés sur tous les pôles de la tension du réseau Sinon il y a danger de mort par choc électrique Ne branchez jamais l appareil sur la tension du réseau immédiatement après un transport d un local froid dans un local chaud p ex lors du transport L eau de condensation qui en ré...

Page 6: ...en perçant les trous de montage ou en vissant l appareil Enlevez le couvercle de la face inférieure qui se trouve du côté du passe câble à vis Pour cela utilisez un tournevis fin et relevez avec précaution les clips du couvercle 4 Le cou vercle est ensuite facile à enlever 5 Dénudez l isolation extérieure du cordon d alimentation sur une longueur de 3 cm environ Dénudez l isolation extérieure des ...

Page 7: ...ts te vinden als de netsnoe ren al polig van de netspanning gescheiden zijn Anders bestaat er levensgevaar door een elektrische schok Sluit het product nimmer onmiddellijk op de netspanning aan als u dat product van een koude omgeving naar een warme omgeving hebt gebracht bijvoorbeeld na transport Het condens dat daarbij ontstaat kan in bepaalde situaties onherstel bare schade aan het product toeb...

Page 8: ...olgens de bevestigingsklemmmen vast met elk twee schroeven 3 Let er tijdens het boren van de montagegaten resp het vastschroeven op dat er geen aanwezige kabels of leidingen worden beschadigd Verwijder de afdekking aan de onderzijde die zich aan de zijde van de kabelwartel Gebruik hiervoor een schroevendraaier en wrik de vier clips van het deksel voorzichtig omhoog 4 Vervolgens kan de afdekking ee...

Reviews: