27/0
1
28/0
Bed Temp
Temperature
Heatbed
Extruder
Ext.Temp
Zwraca
Sound
LED light
Manual
Fan
Stop
Return
Preheat
Filament
Level
System
Tool
1
2
3
Turn off the printer and unplug the power cable before replacing the fuse and let the printer cool down. Never repair
fuses or bridge the fuse holder.
•
Switch the power switch into the off position O and disconnect the printer from the mains supply.
• One spare fuse is stored in the fuse compartment between the power supply socket and power switch.
•
For further fuses, ensure that you only use fuses of the specified type and rated current (see “Technical Data”) as
replacement.
• Use a suitable screwdriver
to open the fuse holder out
of the fuse compartment
carefully.
• Remove the defective fuse and replace it
with a new fuse.
• Carefully push the fuse holder with the
new fuse back into the fuse compartment.
• Reconnect the device to the mains
voltage and take it into operation.
• Loosen 2 screws of the Z sensor on the right to make sure the Z sensor can be pull up and down. Then calibrate the height between
the Z sensor and nozzle with the tool until both of their lower surface are in close contact with the upper surface of the tool, when we
can press the sensor wire to fix it and fasten 2screws of the Z sensor to finish the calibration.
f) Replace fuse