AKT – Operating instruction for refrigerant drier
AKT-1
Appendix KT
Operating instructions
for the refrigerant drier
In this chapter you receive a brief overview for the optionally
installed refrigerant drier.
Please follow the refrigerant drier safety instructions found in
the separate operating manual. It is particularly dangerous to
breath-in the cooling steam or get in contact with the cooling
agents. Smoking when working on the refrigerant drier is pro-
hibited, since the cooling agent will developpoisonous vapours
when getting in touch with the glowing end of a cigarette or oth-
er open flame (e.g. welding work).
The refrigerant air drier contains a cooling system for cooling
the compressed air. The compressed air is also de-humidified.
The condensate created here is discharged through a conden-
sate separator.
Make sure that the air inlet and outlet is never impaired or
blocked. Adequate distance must be maintained between the
ventilation grids and room walls.
Please follow the figure in Chapter 2.3 and the information in
Chapter 2.3.1 of the Operating Manual of the refrigerant drier
supplier.
After turning on the refrigerant drier, wait 5 minutes until the
pressure has equalised. Only then, start the compressor.
Content
Function