AD App Air receiver
AD-1
Appendix AD
Compressed air receiver
No. Description
Function
1
Connection from
compressor
Inlet of compressed air into
the air receiver
2
Safety valve
Protects the air receiver
against too high a pressure
3
Compressed air outlet
Outlet of compressed air to
the c.a. system
4
Condensate drain
Drains the condensate for
collection
•
Please observe the regional laws and regulations for the
control of air receivers and notice the periodic inspections
•
Please take care for a condensate drain system
•
Please take the necessary mesures as to discharge the
condensate if no automatic system
Caution!
To grant the functionality of the air receivers, all flexible hoses of the
receivers have to be changed after 2 years at the latest. This affects
especially the 2 x 90l air receivers. Both receivers have to be able to
be discharged separately.
The number of load changes in the air receiver should not be too high.
Therefore, the compressor is not disconnected from the mains and do
not let the pressure in the receiver fall too low. (purchase quantity <
delivery quantity)
Illustration:
air receiver
Description
of air receiver
1
2
3
4