3 - Installation and start-up
3 - 6
3.3 Compressor start-up
(continued)
When first starting up the machine, as well as after each
change to another electrical feed line, the rotation of the
SCROLL compressor must be checked.
Rotation is anticlockwise seen from the shaft. The rotation of
the V-belt pulleys must be in the direction of the arrow on the
pulley! If necessary, reconnect the connecting cable (qualified
electrician).
Fig. Arrow for direction of rotation
WARNING!
There is a danger from moving parts when checking the rotation
with the cover open!
Proceed as follows when checking the rotation:
Step
Operation:
Figure / Expl.
1
Remove the door and put it
aside
2
Start the compressor by turn-
ing the switch to the right.
3
Within 2 seconds, stop the
compressor by turning the
switch to the left.
Once you determined the correct rotational direction, you can
operate the compressor. The phase must be replaced if the
rotational direction is incorrect.
Checking the
rotational direction
INFO
Summary of Contents for Scroll Line Industry Series
Page 60: ...Appendix T Data sheets 015x765x1462 AT Appendix Data sheets AT...
Page 62: ......
Page 63: ......
Page 64: ......
Page 71: ......
Page 72: ......
Page 73: ......
Page 92: ...A ADS Appendix Pressure Switch AADS 2 Appendix ADS End Pressure Switch...