4 Bedienung im Normalbetrieb
4 - 5
4.4 Remedying malfunctions in normal operation
This section contains advice on remedying malfunctions/faults.
Danger!
Human error in remedying faults or lack of professional training
can lead to serious damage to property or physical injury.
It is therefore essential that faults are rectified by duly qualified
persons.
Always take the following steps before starting any work:
Switch the compressor and main switch off!
Discharge all the compressed air from the compressor and
air vessel!
The following faults may occur during operation:
Fault
Possible Cause
Remedy
Compressor
does not start
•
No power
•
Loose cables or fuses
•
Motor protection
switch has cut out
•
Combistat cut out /
defective
•
Connecting lines to
Combistat are kinked
Establish power
supply
Retighten cables or
fuses
Unlock motor
protection switch
(switch cabinet)
Ensure correct
compressor cooling;
install new Combistat
if defective
Straighten out
connecting cables
Continued overleaf
Contents
Before eliminating
faults
Malfunctions