5 Maintenance
5 - 4
5.1 What to take into account
(continued)
Only original spare parts may be used for the replacement
components such as air filter, drive belts, etc.
Only allow authorised dealers to carry out repair work.
A list of other persons/companies authorised by the manufac-
turer to carry out repairs can be obtained from the manufacturer
on request.
Do not allow repairs to be carried out by any persons other
than those authorised by the manufacturer!
Servicing is carried out as agreed with the authorised dealer.
Take the standard safety precautions and proceed with great
care when carrying out any servicing work.
Please follow especially the points below:
Servicing work to be carried out by qualified personnel only.
Correct tools only to be used for servicing work.
Compressor and power supply to be switched off before any
servicing work is carried out. Take measures to ensure that
the unit cannot be switched on accidentally!
Compressor must be allowed to cool down before carrying
out servicing work to avoid risk of burns!
Compressor to be disconnected from all sources of pres-
sure and all pressure removed before dismounting pressur-
ised parts.
Scrupulous standards of cleanliness to be maintained dur-
ing servicing work; parts and exposed openings to be cov-
ered with a clean cloth, paper or masking tape.
Motor, air filter, electrical components, control equipment,
etc. to be protected from ingress of moisture, e.g. when be-
ing wiped.
No tools, loose parts or rags to be left in or on the unit.
Operating pressures, temperatures, time settings, control
equipment and cut-out devices to be checked for perfect
working order before unit is released for operation after ser-
vicing work.
Doors on the compressor to be closed before switching on
the unit (including for test run)!
Sound-absorbing materials to be left in place and retained.
Spare parts,
accessories
Repairs
General
Notes