The input voltage of AC Power Supply shall not 

exceed 250 V.

For an AC load, operating voltage: ≤ 250 V; 

operating current: ≤ 16 A.

You can choose to connect your switch(es) to 

either, neither, or both of S1 and K1 to your circuit 

on demand.

WARNING

Connect the AC Power Supply to OUT/IN only; 

otherwise Smart Relay may be damaged.

Summary of Contents for RSHSRZ02P

Page 1: ...Smart Relay Zigbee User Manual VERSION A0 ...

Page 2: ...Manual contains instructions for Smart Relay Please read the User Manual carefully before using the device Please avoid exposing the components to direct sunlight Do NOT allow water to enter Smart Relay To ensure quality wireless communication please keep it away from metal objects at a distance of at least 20 cm or 7 88 inches After wiring use PE double sided adhesive to secure Smart Relay to the...

Page 3: ...ire maintenance or repair Smart Relay can only be powered by a DC power supply 8V 30V otherwise Smart Relay will be damaged Risk of electric shock Make sure the power supply is powered off before connection When wiring make sure the wire retainer in the hole is fully opened ...

Page 4: ... supply 8V 30V Wiring holes V V Function Connecting to a push button switch to turn devices on or off K1 Connecting to a rocker switch to turn devices on or off S1 Connecting to the fire wire of an AC power supply or the positive terminal of a DC power supply IN Connecting to the positive side of the load OUT ...

Page 5: ...e current operating status of Smart Relay Flashing Restoring to factory settings and waiting for network distribution flashing for 3 minutes On Relay status ON Off Relay status OFF LED light Part OUT IN S1 K1 V V Button LED light ...

Page 6: ...Diagram AC Power Supply N L AC load DC Power Supply Negative Positive Rocker switch Push button switch AC Load Function Press Power on off Smart Relay Long press for 5s Factory reset Button Part OUT IN S1 K1 V V ...

Page 7: ...0 V For an AC load operating voltage 250 V operating current 16 A You can choose to connect your switch es to either neither or both of S1 and K1 to your circuit on demand WARNING Connect the AC Power Supply to OUT IN only otherwise Smart Relay may be damaged ...

Page 8: ... input voltage of DC Power Supply shall not exceed 30 V For a DC load operating voltage 30 V operating current 16 A DC load DC Power Supply Negative Positive Rocker switch Push button switch DC Load OUT IN S1 K1 V V ...

Page 9: ...thod 3 Turn on off the rocker switch connecting to S1 10 times continuously Factory Reset Smart Relay should be used in association with Renogy ONE For more detailed instructions please refer to the User Manual of Renogy ONE Add Smart Relay Zigbee to Renogy ONE You can choose to connect your switch es to either neither or both of S1 and K1 to your circuit on demand ...

Page 10: ...HSRZ02P Parameter Model Name Value IEEE 802 15 4 2 4GHz Zigbee 8 30V DC Power Supply 250V AC 30V DC 16A Max Load 20 C 40 C 4 F 104 F Operating Temperature 0 90 RH Operating Humidity 20 x 40 x 44 mm 0 79 x 1 57 x 1 73 in Dimensions ...

Page 11: ...at Smart Relay is in normal state Ensure there is no any corrosion insulation damage or discoloration marks of overheating or burning For additional support contact the Renogy technical support team through renogy com contact us Have the following information available when contacting Renogy Technical Support Owner name Purchase channel Contact information Serial number Order number Brief descript...

Page 12: ...incidental which might arise out of the use of information in the User Manual Renogy is not responsible or liable for the failures damages or injuries resulting from repair attempted by unqualified personnel or improper installation and operation The illustrations in the User Manual are for demonstration purposes only Details may appear slightly different depending on product revision and market reg...

Page 13: ... for grid power Live Sustainably with Renogy Did you know In a given month a 1KW solar energy system will Save 170 pounds of coal from being burned Save 300 pounds of CO2 from being released into the atmosphere Save 105 gallons of water from being consumed PLUS Renogy Power Renogy Power Plus allows you to stay in the loop with upcoming solar energy innovations share your experiences with your sola...

Page 14: ...he contents of this manual without notice Visit renogy com to find relevant documentation or get more support via Contact Us RENOGY COM Join the Renogy Power Plus Community by downloading the DC Home App Find your e warranty here and more ...

Reviews: