Possible configurations of the pistons present in the cover:
electrical connection procedures
• Connect the power supply wires of the fans and the rev counter (if present) to
the connector in the side brake casing, taking care of the polarity. The electronic
card that controls the fans requires this prescription. The same attention also
applies to the connections of the tachometer sensor in the models that provide it;
in addition to the power contacts, there is also the pulsating signal that will be
processed by the PLC
• Some types of double-pole or multi-pole connectors are used which are mounted according to the brake equipment
or customer specifications.
TRIPOLAR CODE CNTH100P3
EN17530-803 three-pole connector
Cable diameter 2,5 mm
Rated voltage max 300 V AC
Maximum range 16 A
C-VDE insulation
Degree of protection IP 65
Screw connection
Used for fans connection
• Connect positive pole 90° times from neutral
• Connect negative pole opposite connector