103
Endura
®
Delta
en
User
10.2.5.1.9 • Error code list
You can see which error messages have occurred using this menu.
Every error message is indicated by a code and is linked to the time
at which the error occurred. By tapping the error code in the app, an
initial explanation opens and then solutions are proposed. You can read
Chapter 11 for the exact meanings of the error messages.
You can delete the error message list. The unit is restarted and you will
probably have to repair the link.
10.2.5.1.10 • C-mode
You can activate the
“C-mode” (design
position) using this menu.
If the C-mode is active,
then the Endura Delta
will nominally ventilate
for 30 minutes. You can
calibrate the system
during this half hour
by adjusting the supply
and extraction valves.
The flow rates must
be verified when the
C-mode is activated.
As long as the
C-mode is active, the
following main screen
is displayed:
You can interrupt the
C-mode by clicking
the X next to the timer.
10.2.5.1.11 • Restarting the unit
“Restart device” is not the same as “reset device” (see 10.2.5.1.14).
“Restart” means that only the unit is restarted. No settings will be deleted.
“Reset device” means that all of the settings are deleted and the default
factory settings will be restored.