34
Endura
®
Delta
en
Installer
The majority of the connections to the Endura Delta have been pre-assembled. However, you
can choose to connect a number of extra functions. Below are the options that can be connected
afterwards:
7.1.1 • Connecting the Master TouchDisplay (no. 24 in the picture)
A TouchDisplay is already integrated into the unit as standard (only for types 380 and 450). You
can set and control the unit using this. It is highly advisable to control and configure the unit using
the RENSON
®
Ventilation app for smartphones and tablets. The app can be downloaded for free
from the App Store (Apple iOS), Google Play Store (Android) or Windows Store (Windows).
However, you can opt to install an external Master TouchDisplay. This Master TouchDisplay is
equipped with a CO
2
sensor. It is best to place this in a room where you want to be able to
register the CO
2
levels and, if necessary, allow the ventilation flow rate to respond to this.
The Master TouchDisplay is connected to the main printed circuit board (24) using a cable (max.
30 m, section of 4 x 0.22 mm² up to 4 x 1 mm²). The Master TouchDisplay is powered by the
unit, so it does not have to be connected to the home’s electricity grid.
L PE N
50Hz
230V AC
24V
0V
RX IN
TX OUT
24V
0V
TX OUT
RX IN
RX IN
TX OUT
RX IN
TX OUT
24V
0V
TX OUT
RX IN
Power cable type
JT003-ST3 (included)
connected via IEC
connector at the top of
the unit
Data + power cable
2 x 0.34 mm² (data)
2 x 1.00 mm² (power)
impedance data 120 Ω