31
Endura
®
Delta
en
Installer
6.2.6 • Positioning the valves
• Take the following practical issues into account when positioning the valves:
− The supply valves must be installed in dry rooms. Discharge valves must be installed in wet
rooms.
− RENSON
®
recommends using valves with a diameter of 125 mm everywhere.
− The distance between the supply valves and the discharge valves must be as large as
possible. This is to guarantee the optimum distribution of fresh air throughout your home.
For example, it is important not to have the supply point for the living room too close to the
extraction point for the open kitchen.
− Also take the layout of your home into account when determining the positions of the valves.
For example, it is a good idea not to place a supply valve right above your sofa. This is to
avoid possible draughts on people.
− In order to avoid any flow noise at the valve, an additional soundproofing foam can
be placed behind the valve. This can only be done if the valve diameter of 125 mm is
respected. The use of acoustic foam reduces the diameter of the duct.
6.2.7 • Installing the Master TouchDisplay and air quality sensors
A TouchDisplay is already integrated into the unit as standard (only for types 380 and 450). You
can set and control the unit using this. It is highly advisable to control and configure the unit using
the Endura Delta app for smartphones and tablets. The app can be downloaded for free from the
App Store (Apple iOS), Google Play Store (Android) or Windows Store (Windows).
However, you can opt to install an external Master TouchDisplay (Main Controller). This Master
TouchDisplay is equipped with a CO
2
sensor. It is best to place this in a room where you want to
be able to register the CO
2
levels and, if necessary, allow the ventilation flow rate to respond to
this.
The Master TouchDisplay is connected to the main printed circuit board using a cable (see
Section 7.1.1 for the electrical connection diagram) (specs, max length). The Master TouchDisplay
is powered by the unit, so it does not have to be connected to the home’s electricity grid.
You can link multiple air quality sensors (Sensor Controller) to the Master TouchDisplay. These air
quality sensors communicate wirelessly with the Master TouchDisplay and must be connected to
the home’s electricity grid (230 V).