2 Installation
Have your stove installed by a recognized installer only. He is able to assess your specific situation and
provide you with an appropriate advice.
2.1 Dimensions
Top connection
Rear connection
2.2 Chimney
One of the main components of the stove is the chimney. Together with the chimney, the stove is one unit.
The stove can only perform properly if the stove and the chimney have been aligned correctly. Therefore
you should have these inspected by the installer in advance. In addition, the chimney should be clean
and leak-proof and have a minimal diameter of Ø 150 mm over the entire length. Optimal performance
is achieved with a chimney draw of 12 Pa. A properly functioning chimney prevents a lot of issues such as:
•
Poor heat transfer
•
Soot on the windows
•
Smoke in the room
•
Chimney fires.
In case of a chimney fire you need to immediately seal all air supply channels (primary and secondary).
Then, you should immediately call the fire department. After the fire has been extinguished, the stove and
the chimney should be inspected again by your installer.
2.3 Converting from top to rear connection
The stove is equipped with a top connection in the factory. The construction of the stove allows an easy
conversion to a rear connection. Attachment 1 shows plans that will further explain the different compo-
nents. The conversion is done as follows:
1. Remove the wood collector.
a. Slide the wood collector up in the doorway.
b. Then the wood collector can be easily removed by rotating it 90°.
2. Remove the bottom grid.
a. The bottom grid is not attached and can be removed without problems.
3. Remove the vermiculite panels
a. First slide the panels on the side downwards.
b. Then rotate these 90° to be able to remove them through the doorway.
c. Now the rear panels can be removed.
4. Remove the cover
a. Slide the cover upwards so that it can be removed from the outer sheath.
4
800
544
414
Ø150
136
23
Ø150
604
800
544
414
23
19