background image

PORTABLE 

OZONIZER

Instruction manual

Summary of Contents for CH-BP

Page 1: ...PORTABLE OZONIZER Instruction manual ...

Page 2: ...NFIGURATION FUNCTION 2 GENERAL OPERATING INSTRUCTIONS 3 BP SERIES INSTRUCTION 4 ZTW SERIES INSTRUCTION 5 DP SERIES INSTRUCTION 6 APPLICATIONS 8 AFTER SALES SERVICE 9 PACKING LIST 9 APPENDIX 10 PORTABLE OZONIZER PARAMETERS 10 Please read the instruction manual carefully before using the machine Please keep it in a safe place for future reference ...

Page 3: ...e control Anion function DEVICE CONFIGURATION FUNCTION Chuanghuan portable ozonizer is widely used to sterilize disinfect and eradicate odours from places such as households businesses offices hotels food processing stations etc Operating the device is simple and practical Stable ozone output is a necessary condition for the machine to operate The various models of portable ozonizer feature the fo...

Page 4: ...k could occur Place your device out of children s reach Cleaning and maintenance Before cleaning the device first turn off the power and unplug the power plug from the electrical outlet Accidentally starting the device during cleaning may result in personal injury or damage to your equipment Please use a dry cloth to clean the device Do not use flammable solvents such as alcohol benzene or thinner...

Page 5: ... a fire or electrical shock OPERATING INSTRUCTIONS 1 Unscrew the bolted cap on ozone output connect with the equipped corrosion resistance hose Then screw the bolted cap back lead the hose to the place where ozone is needed Attention Make sure the ozone output hose is smooth without knots Do not direct the ozone output directly towards people 2 Connect power 3 Turn on power switch The power supply...

Page 6: ...l pressure reducing valve for high pressure as a result of 18Mpa oxygen pressure In order to avoid cases of oxygen cylinder explosion a test instrument should be installed in the oxygen supply pipe to test the alarm system Note see other operating methods in the related general instructions section ZTW MANUAL 1 ZTW series of external gas source type Gas supply should be clean dry air or oxygen As ...

Page 7: ...instrument should be installed in the oxygen supply tube to test the alarm system 3 Set the working time The letters in the middle of timer H M S represent the hour minute second respectively The longest time you can set is 99h 99m When the intermediate letter is H it will show the number of hours on the left and the number of minutes on the right when the letter is M it will show minutes on the l...

Page 8: ...DP Series II models on the remote control 1 Checking status automatic checking voice slower beeping Ozone indicator OZONE Lamp flashing 2 From 00 01 to 99 59 hours of operation can be set freely 3 Press optional key to exit and shutdown status 4 Start up delay time 15 seconds after start up ozone output Ozone indicator light on Shutdown delay time 30 seconds before shutdown no ozone output Ozone i...

Page 9: ...etting Long press SET key then after hearing a long beep Setting hour short press SET key the nhouT light is flashing You can press ADD or SUB key to set hour Setting the minutes short press SET key the minutes light is flashing You can press ADD or SUB key to set the minutes After finish setting then short press confirm key Step 3 working Short press on off key machine works as the mode setting A...

Page 10: ...t before ex works Any showing under normal operation conditions will be repaired or replaced free of charge by our company with this warranty card after it is checked by our company as the case start from the date of purchase Following conditions are not covered by the warranty Dismantling by user and operating not in accordance with instruction listed in instruction manual Altered power supply or...

Page 11: ...0 ø 6 3 220 50 370x160x295 5 6 CH BT 10 6 110 ø 6 3 220 50 365x165x275 6 1 CH BP Portable ozonizer Model Gas flow rate L mim Ozone output g h Power ff Output gas tube mm Fuse A Voltage V Hz External Size mm Net kg CH BP3G 45 3 no ø 6 3 220 50 390x230x310 8 6 CH BP5G 45 5 120 ø 6 3 220 50 390x230x310 8 6 CH BP6G 45 6 140 ø 6 3 220 50 390x230x310 8 8 CH BP7G 45 7 150 ø 6 3 220 50 390x230x310 8 8 CH ...

Page 12: ...fspareparts com www lfspareparts724 com EPGC S a s 13 Rue des Forts 59960 Neuville en Ferrain France T 33 3 20250621 epgc epgc com www epgc com Commercial Catering Spares Ltd Block C Axis Point Hill Top Road Heywood Lancashire OL10 2RQ UK T 44 1706 621 155 info ccspares co uk www ccspares co uk Atel S r l a socio unico Via Selvuzzis 51 2 33100 Udine UD Italy T 39 0432 602095 info atelitalia com ww...

Reviews: