8
DP SERIES MANUAL
Panel Operation Instruction:
1. “MODE” 3 kinds of working model. F1, F2-1 and F2-2.
Mode F1 = set a limit work time
Mode F2-1 = work - downtime cycle
Mode F2-2= downtime-work cycle
2. “Time”Show the running time of each working mode.
3. The power indicator: Work status - lamp always being on;
Downtime status - lamp flashing.
4.Ozone indicator: Downtime status - lamp off, work status - lamp on, stop work status - lamp flashing.
PANEL FUNCTION KEYS INSTRUCTION:
DP models are equipped with the first generation of the remote control. You can select the device remote control mode
that corresponds to F1 operation mode MODE1, MODE2 F2-1 corresponding operating mode, MODE3 F2-2 corresponding
operating mode. 03 and Anion function keys above applies to the DP Series II models on the remote control.
1. Checking status: automatic checking voice (slower beeping); Ozone indicator (“OZONE” Lamp flashing)
2. From 00:01 to 99:59 hours of operation can be set freely.
3. Press optional key to exit and shutdown status.
4 Start up delay time:15 seconds after start up, ozone output, Ozone indicator light on. Shutdown delay time:30 seconds
before shutdown, no ozone output. Ozone indicator light flashing.
Noted: If the machine has been running for less than 15 seconds, briefly press the ON/OFF key. The machine stops working,
the ozone indicator light goes off.
1. Power LED
2. MODE
3. Ozone LED
4. Work Time
5. 1R
6. Start Key
7. Confirm Key
8. Add Key
9. Subtract Key
10. Set Key
11. Ozone Output
ON/OFF
INDICATOR LIGHT
OZONE
MODE 1
MODE 2
MODE 3
ANION
SET
SUB
ADD
CONFIRM
ON/OFF
Set/Switch working
model/confirm selection/
switch hour and minute
Decrease/Increase
working mode & time
Save and confirm
Start up/Shutdown
REMOTE CONTROL