3.2 Status

 

When all settings have been done under the Basic tab, the Status tab shall be accessed. By 
clicking the Refresh button on the upper left side, the signal strength can be monitored. In order 
to get a good connection, signal strength of 100% is recommended. This corresponds to an RSSI 
value of 33. Usually, a good connection is established if the RSSI value is 25 or higher (signal 
strength of 75%). If the signal strength is lower than this, try to adjust the receiver antenna in 
order to maximize the RSSI value. 

 

When the signal strength is optimized, click the Refresh button in the lower, right corner of the 
screen until your modem has received an IP address from the network. When this is done, the 
connection is established and the connection is configured. 

Measure with CPE signal lead on the back of the unit 

The middle led is by default set to Pulse method and shows the signal in 7 steps. 

No pulse Not associated 

1 pulse 1 -9 dB signal 

2 pulses 10 -14 dB signal 

3 pulses 15 – 19 dB signal 

4 pulses 20 – 24 dB signal 

5 pulses 25 – 29 dB signal 

6 30 dB signal 

 

 

3.3 Encryption

 

 

If the wireless network uses WEP or WPA encryption, the keys or pass phrase must be 
configured in the modem. To adjust encryption settings, access the tab security. Under 
Encryption Settings, change the selection from Disabled to either WEP 128-bit, WEP 64-bit, 
WPA1 or WPA2 depending on what details you ISP has given you. 

 

 

Summary of Contents for SU-100 MIMO

Page 1: ...uld mount the radio modem on the top of your roof or at the TV antenna pole Note SU has to be installed by qualified installer and configured respecting maximum E I R P values allowed by ANATEL Regulations 1 1 General information When connecting disconnecting the SU to a computer it is important to follow the instructions in this document System Requirements One available Ethernet port Web browser...

Page 2: ...d when the computer is connected to the subscriber unit 1 4 Subscriber Unit settings When the subscriber unit is delivered its IP address is set to 192 168 50 1 The built in DHCP server delivers IP addresses in the range 192 168 50 2 100 2 User Interface The subscriber unit is configured in a browser window Start your browser and type the following line in the address field http 192 168 50 1 Press...

Page 3: ... Internet Service Provider Rate AUTO Mbit SSID See the How to connect to a network description below DATA VLAN 0 When all changes are made press the Apply button How to connect to a network Ensure that the correct frequency range is chosen Press the Site Survey button and wait 20 30 seconds until the scan is performed The network that your service provider has set up should be visible in the Site ...

Page 4: ...orner of the screen until your modem has received an IP address from the network When this is done the connection is established and the connection is configured Measure with CPE signal lead on the back of the unit The middle led is by default set to Pulse method and shows the signal in 7 steps No pulse Not associated 1 pulse 1 9 dB signal 2 pulses 10 14 dB signal 3 pulses 15 19 dB signal 4 pulses...

Page 5: ...mation for the correct setting WPA1 and 2 The modem supports both WPA1 and WPA2 with PSK Pre Shared Key and encryption algorithms TKIP and AES CCMP Choose the correct WPA and encryption method according to your information from the ISP Enter the correct pass phrase which should be between 8 and 63 characters long Only use alphanumerical characters and avoid country specific characters like å ä and...

Reviews: