8. COMPUTER INTERFACE 

8.1 communication interface 

The communication interface (DB9 port) on the back of the UPS may be 

connected to a host computer. The port provides two different modes for 

communicating with the computer like below. 

1. Supply dry contact function (like RUPS of Megatec Company) 

The port simulates relays closing to communicate with the computer. Its 

major functions are as follows. 

(1) To broadcast a warning when power fails. 

(2) To close any open files before the battery exhausted out. 

(3) To turn off the UPS. 

2. Supply RS-232 for monitoring software (like 

RUPSII 

or 

UPSilon 2000

 of 

Megatec Company) 

The UPS communicates with the computer by sending out RS-232 data 

streams to one of the serial ports. By this method the user is able to monitor 

the following parameters. 

Input Voltage 

Indicates the present input voltage to the UPS 

system when AC power is present. 

Output Voltage

Indicates the present output voltage of the UPS. 

AC Frequency 

Indicates the actual output frequency of the UPS. 

Battery Voltage

Indicates the present DC voltage of the UPS 

battery. 

Temperature 

Indicates the actual temperature inside the UPS. 

 

27

8.2 DB9 PIN Assignment 

PIN 2: RS232 RXD 

PIN 3: RS232 TXD 

PIN 5: GND   

The other PINs have no function. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DB9 INTERFACE CONNECTOR

Summary of Contents for RP-UPH

Page 1: ...rruptible Power Supply 1 CONTENTS 1 INTRODUCTION 2 2 SAFTY INSTRUCTION 3 3 SYSTEM DESCRIPTION 6 4 CABLE CONNECTION 14 5 OPERATION 15 6 TROUBLE SHOOTING GUIDE 21 7 OPERATION MODES OF THE UPS 24 8 COMPU...

Page 2: ...weight and compact size easy to transport and place 1 3 Important Notices To be sure that the UPS will be operated correctly the following items should be noticed 3 1 Read instructions carefully befo...

Page 3: ...ds or other foreign objects can enter the UPS system 5 2 5 Maintenance and Service 1 Caution risk of electric shock Even after the unit is disconnected from the mains power supply building wiring sock...

Page 4: ...ect Down key 3 It is pressed to select downward the UPS status on LCD Display 7 Display Function LCD Display 1 This indicates the UPS operation information including UPS status input output voltage in...

Page 5: ...8 2KVA 3KVA Tower Case 9 1KVA 2KVA 3KVA Rack Mount Case...

Page 6: ...e Protection 8 Breaker 4 Remote Control Detachable LCD Panel Option 9 Input Socket 5 Output Socket NEMA or IEC 11 1KVA Rack Mount Case 1 Fax Modem Surge Protection 6 Input Socket 2 DB 9 RS 232 Interfa...

Page 7: ...tion 9 Breaker 5 Output Socket NEMA or IEC 10 Input Socket 13 2KVA 3KVA Rack Mount Case 1 Breaker 7 DB 9 RS 232 Interface Port 2 Remote Control Detachable LCD Panel Option 8 Input Socket 3 External Ba...

Page 8: ...is model is with socket types only NEMA or IEC Simply plug the load power cord to the output sockets to complete connection 15 5 Operation 5 1 Check Prior to Start Up 1 Ensure the UPS is in a suitable...

Page 9: ...S is stored over 3 months please keep supplying power to the UPS for at least 24 hours to ensure battery fully recharged 5 4 LCD Display Use Up Down key to select menu displays of the LCD described be...

Page 10: ...w and HI high In this screen press on off Control Key to enter the following steps for LO HI voltage setting B The cursor will pop up to indicate the item newly selected Press on off Control Key to ge...

Page 11: ...ected press on off Control Key again to save the data 21 6 Trouble Shooting Due to careful design and strict tests of our products fail of UPS seldom occurs However once they do fail in some situation...

Page 12: ...per 0 5 second Please reduce the critical load to 100 23 5 AC utility power is normal but the load is supplied by AC utility power via bypass Output power is more than 150 Warning LED lits up and buz...

Page 13: ...DC AC inverter and static switch to support power to load The battery charging voltage comes from AC utility input and converted by AC DC charger to support battery charging power 25 7 3 AC Utility Fa...

Page 14: ...pply RS 232 for monitoring software like RUPSII or UPSilon 2000 of Megatec Company The UPS communicates with the computer by sending out RS 232 data streams to one of the serial ports By this method t...

Page 15: ...465 200 352 465 200 352 Specifications are subject to change without notice 9 SPECIFICATIONS 29 9 2 Tower Case 120V Rated Power Capacity 1KVA 700W 1 5KVA 1050W 3KVA 2100W Input Voltage 60 138VAC Base...

Page 16: ...8 Specifications are subject to change without notice 31 9 4 Rack Mount Case 120V Rated Power Capacity 1KVA 700W 1 5KVA 1050W 3KVA 2100W Input Voltage 60 138VAC Base on load percentage 110 70 60 50 50...

Page 17: ...32...

Reviews: