2.3 Important notices 

1. Caution - risk of electric shock. 

  Even after the unit is disconnected from the mains power supply (building   

  wiring socket outlet), components inside the UPS system are still     

  connected to the battery and are still electrically live and dangerous.   

  Before carrying out any kind of servicing and/or maintenance, disconnect 

the batteries and verify that no current is present. 

2. Only persons adequately familiar with batteries and with the required 

precautionary measures may exchange batteries and supervise operations. 

Unauthorized persons must be kept well away from the batteries. 

3. Batteries may cause electric shock and have a high short-circuit current. 

Please take the precautionary measures specified below and any other 

measures necessary when working with batteries: 

  - remove wristwatches, rings and other metal objects 

  - use only tools with insulated grips and handles. 

4. When changing batteries, install the same number and same type of 

batteries. 

5. Do not attempt to dispose of batteries by burning them. This could cause 

battery explosion. 

6. Do not open or destroy batteries. Escaping electrolyte can cause injury to 

the skin and eyes. 

7. Ensure that no fluids or other foreign objects can enter the UPS system. 

 

 

Summary of Contents for RP-UPH103T

Page 1: ...User manual RP UPH 6K 10K ON LINE UPS REV 2...

Page 2: ...Contents 1 Introduction 1 2 Safety Instructions 2 3 System Description 4 4 Installation 8 5 Operation 9 6 Trouble Shooting Guide 14 7 Communication 15 8 Specification 16...

Page 3: ...start function 3 LED and LCD display for detail status and data real time alarm silence 4 Remote monitoring with SNMP intelligent slot and RS 232 interface 5 Light weight and compact size easy to tra...

Page 4: ...S on rugged or declined surface 2 Do not install the UPS system near water or in damp environments 3 Do not install the UPS system where it would be exposed to direct sunlight or near heat 4 Do not bl...

Page 5: ...supervise operations Unauthorized persons must be kept well away from the batteries 3 Batteries may cause electric shock and have a high short circuit current Please take the precautionary measures s...

Page 6: ...battery voltage battery capacity left output load and inside temperature UPS output voltage frequency can be set from it here too 2 Up key Press Up key to select upward Switch Off press both Up key 2...

Page 7: ...ine mode press and hold both Up key 2 and Enter key 4 simultaneously for 3 seconds to initiate the self test 10 seconds 5 Fault LED red To indicate the UPS has an internal fault 6 Warning LED yellow T...

Page 8: ...6 3 2 OUTLINE 6K 10K Tower...

Page 9: ...port 3 EPO connector 4 Parallel connection 5 Intelligent slot 6 Fan 7 External battery connector 8 Input breaker 9 Input Output terminal 10 Classic ground screw 11 Maintain bypass switch 12 IEC Circui...

Page 10: ...insulated wire which complies with AWG Standard for the UPS input and output wirings 4 To connect the load with the UPS please turn off all the loads first then perform the connection and finally tur...

Page 11: ...ready to switch on the inverter 2 By pressing the Enter key and the Down key simultaneously for 3 seconds the UPS will start up after two beeps and Normal LED lights up to indicate the power is from i...

Page 12: ...10 5 4 LCD display Use Up Down key to select menu displays of the LCD described below This screen will refresh once the system power is enabled 1 Rated specification 2 Status 3 Voltage 4 Frequency...

Page 13: ...11 5 Battery status 6 Output power 7 Temperature...

Page 14: ...ng range the bypass output will be closed automatically to protect the load In this screen press Enter key to enter the following steps for LO HI voltage setting B The cursor will pop up to indicate t...

Page 15: ...ltage and frequency Press Enter key to confirm voltage and then the cursor will move to frequency selection The output voltage 208V 220V 230V or 240V are available The output frequency 50Hz 60Hz 50HzP...

Page 16: ...ase contact your agent for service 3 AC utility power is normal but UPS is overloaded Warning LED lits up and buzzer beeps But UPS has not switched to bypass Please reduce the critical load to 100 4 A...

Page 17: ...S400 card to achieve remote management of the UPS Please contact your local distributor for further information 2 The following are the descriptions and pin assignment of RS232 DB 9 port Baud rate 240...

Page 18: ...Hz 60Hz 0 1Hz Outlet Terminal blocks IEC outlet 2 Wave form True sine wave Frequency lock range 50Hz 60Hz 4Hz Overload Line mode 100 110 10minutes 110 130 1 minute 130 1 second Overload Battery mode 1...

Reviews: