background image

INTRODUCTION 

 

System Description

 

 

The product is line interactive UPS with the newest technology and powerful 

function. The Line Interactive UPS is with AVR function allows input voltage 

range from 75% to 125%, including on line voltage boost-up & buck down. 

An ideal protection equipment for critical connected loads. 

 
In addition, This UPS provides advanced single telephone line or modem 

surge suppression through the modular connectors on the back panel. 

 
The Line Interactive UPS and RUPS2000 monitoring software (Optional kits) 

makes our computer operate intelligent and provides you with the ability of 

perfect protection of your critical devices. 

 

Features 

 

¾

 

Line interactive design. 

¾

 

Easy LED display. 

¾

 

Provide boost and buck AVR to stabilize input voltage. 

¾

 

Provides lightning, surge, overload, and short-circuit protection. 

¾

 

Built-in CCCV battery charger and battery over drain protection. 

¾

 

Auto restart when AC recovery. 

¾

 

Cold start function (Dip power on). 

¾

 

Tel / Modem / Fax / Internet surge suppression. 

¾

 

Option Bundle software

Automatically save your valuable files before 

auto shutdown. 

 

 

 

 

- 2 -

 

 

TROUBLE SHOOTING 

 

If the UPS failed to operate properly, please review the following checks 
firstly. If the problem remain, please consult sales agent for service. 
 

„

  Is the Master power switched on? 

„

  Is the UPS plugged into a correctly working outlet? 

„

  Is the line voltage within the rating specified? 

„

  Is the fuse on the rear panel blown? 

„

  Is the UPS over loaded? 

„

  Is battery not fully charged? Dead battery? Charger failure? 

 
Please provide the following information when call for service. 
1. 

Model number, serial number. 

2. 

Date of the problem occurred, date of purchase. 

3. 

Full description of the problem including load, LED, and alarm status, 
installation condition, working environment, etc. 

 

Trouble-Shooting Chart 

Problem Possible 

Cause

Caution 

To 

Take 

Front panel switch 

in off position. 

Turn on switch. 

Rear panel fuse 

burnout. 

Replace fuse restart UPS. 

No light, and no alarm 

(UPS not on) 

Power cord lose 

Check input power. 

Power cord lose 

Check input power. 

No

Green LED

light, and alarm beeps 

every 3 seconds. 

AC Fuse burnout.

Replace fuse, if problem 

remains, call for service. 

Backup time is less 

than the rating. 

Battery is not fully 

charger failure. 

Recharge the battery for at 

least 6 hours, re-test the 

backup time. If problem 

remains, call for service. 

 

 

- 11 -

 

Summary of Contents for RPT-1000A

Page 1: ...Use With Computer Loads Only Intelligent Auto Shutdown Software Power Surge Noise Protection Internet Line Protection Cost Efficiency AVR Protection Compact Reliable Design U US SE ER R S S M MA AN N...

Page 2: ...that the UPS has to offer Please save this manual It includes important instructions for the safe use of this UPS and for obtaining factory service should the proper operation of the UPS come into que...

Page 3: ...rating of the UPS Below 1 2 or 1 3 of rated power is recommended for longer backup time longer battery life Do not place the UPS near excessive humidity under sunshine or close to heat emitting sourc...

Page 4: ...Cut off No battery drain after cut off Physical Dimension D W H 385 94 170 mm Operating Temperature 32 104 at full load 0 90 relative humidity non condensing Environment Noise Level Less than 40db at...

Page 5: ...9 Pin Female Connector Signal High Min 3 Second Contacts Normally Open Low Battery Mains Failure Pin Number UPS Shut Down 5 8 6 3 1 4 7 2 9 8 OVERVIEW Front Panel 1 Master Power Switch Turn on off the...

Page 6: ...2 FEATURES 2 3 SYSTEM CONCEPT BLOCK DIAGRAM 3 NORMAL OPERATION 3 AC UTILITY FAILURE 4 4 OVERVIEW FRONT PANEL 5 REAL PANEL 5 PICTURE 5 5 INSTALLATION AND OPERATION 7 6 COMPUTER INTERFACE 8 7 BATTERY FA...

Page 7: ...re auto shutdown 2 TROUBLE SHOOTING If the UPS failed to operate properly please review the following checks firstly If the problem remain please consult sales agent for service Is the Master power sw...

Page 8: ...ing the unit Recharge batteries every 3 months is necessary if it is not in use because it may cause batteries over drain WARNING Only a qualified technician should replace the battery Batteries have...

Page 9: ...hemical fumes Check the identification label to verify the UPS voltage and power rating match the available line voltage and load requirements Installation 1 Check if the main switch on the UPS front...

Page 10: ......

Page 11: ......