32-5035-08  

5

User’s Information

NOTE THE LOCATION OF THE MANUAL MAIN GAS SHUTOFF VALVE FOR YOUR FURNACE. 

Have your installer or servicer show you the location if you have any 

q

uestions.

UPFLOW FURNACE Manual Main Gas Shut-off Valve May Be Located on the Left or Right Side

DOWNFLOW FURNACE Manual Main Gas Shutoff Valve May Be Located on the Right or Left Side

AUTOMATIC GAS VALVE

WITH SHUTOFF

AUTOMATIC GAS VALVE WITH 
SHUTOFF

MAIN MANUAL 
SHUTOFF 
VALVE

HORIZONTAL FURNACE Manual Main Gas Shut-off Valve May Be Located on the Top or Bottom Side

Summary of Contents for Condensing Gas Furnaces

Page 1: ...nce WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department DO NOT RELY ON SMELL ALONE TO DETECT LEAKS DUE TO VARIOUS FACTORS YOU MAY NOT BE ABLE TO SMELL FUEL ...

Page 2: ...tear out and spraying may generate fiber concentrations requiring additional respiratory protection Use the appropriate NIOSH approved respirator in these situations FIRST AID MEASURES Eye Contact Flush eyes with water to remove dust If symptoms persist seek medical attention Skin Contact Wash affected areas gently with soap and warm water after handling WARNING SAFETY HAZARD IMPROPER INSTALLATION...

Page 3: ...so air openings provided to the area in which the fur nace is installed and the space around the furnace shall not be blocked or obstructed Keep this in mind should you choose to remodel the area which contains your fur nace If additional insulation is added after the furnace is installed the area around the furnace must be in spected to ensure it is free and clear of insulation If this furnace is...

Page 4: ...tart the Furnace Your furnace will have a switch to turn the gas ON or OFF 5 Turn the external main gas shutoff valve and the toggle switch located on the main gas valve inside the unit to the ON position see illustration on this page 6 Replace the furnace front access panel 7 Turn on main electrical supply and set comfort control to desired setting Combustion blower will start and ignition device...

Page 5: ...any questions UPFLOW FURNACE Manual Main Gas Shut off Valve May Be Located on the Left or Right Side DOWNFLOW FURNACE Manual Main Gas Shutoff Valve May Be Located on the Right or Left Side AUTOMATIC GAS VALVE WITH SHUTOFF AUTOMATIC GAS VALVE WITH SHUTOFF MAIN MANUAL SHUTOFF VALVE HORIZONTAL FURNACE Manual Main Gas Shut off Valve May Be Located on the Top or Bottom Side ...

Page 6: ...way into the filter rack Replace blower access door A bottom return air inlet as shown fea tures a 17 x 25 x 1 filter in the 17 1 2 wide furnace cabinets a 20 x 25 x 1 filter in the 21 wide models and a 24 x 25 x 1 filter in the 24 1 2 wide cabinet For vertical UPFLOW ONLY a left or right return air inlet as above left side shown requires trimming of the factory supplied filter to 17 x 25 x 1 for ...

Page 7: ...e filter grille The filter grille could be in a hallway wall or in the ceiling Check with your deal er for the exact location of your filter and the method of changing the filters REQUIRED FILTERS BOTTOM CABINET WIDTH FILTER QUANTITY SIZE 17 1 2 1 17 X 25 X 1 21 1 20 X 25 X 1 24 1 2 1 24 X 25 X 1 REQUIRED FILTERS SIDE CABINET WIDTH FILTER QUANTITY SIZE 17 1 2 1 17 X 25 X 1 21 1 17 X 25 X 1 24 1 2 ...

Page 8: ...cal power to the furnace and contact a qualified service agency Keep your furnace looking like new for years Clean the enamel finish of your furnace with ordi nary soap and water For stubborn grease spots use a household detergent Lacquer thinner or other syn thetic solvents may damage the finish Problem Possible Trouble Possible Remedy No Heating Blower does not operate 1 Thermostat set incorrect...

Page 9: ...UP PLY FAIL TO SHUT OFF SHUT OFF THE MANUAL GAS VALVE TO THE FURNACE BEFORE SHUTTING OFF THE ELECTRICAL SUPPLY FAILURE TO FOLLOW THIS WARNING COULD RE SULT IN PROPERTY DAMAGE PERSONAL INJURY OR DEATH 1 GENERAL INSPECTION Examine the furnace installation for the following items a All flue product carrying areas external to the furnace i e chimney vent connector are clear and free of obstruction b T...

Page 10: ...equired For best operation burners must be cleaned annually using brushes and vacuum clean er NOTE On LP propane units due to variations in BTU content and altitude servicing may be required at shorter intervals 5 HEAT EXCHANGER FLUE PIPE These items must be inspected for signs of corrosion and or de terioration at the beginning of each heating season by a qualified service technician and cleaned ...

Page 11: ...uding secondary heat exchanger without charge F O B nearest Parts Distribution point or allow a credit in the amount of the then current wholesale price of an equivalent heat exchanger toward the purchase price of a comparable heating unit Any local transportation related service labor air filters and diagnosis calls are not included This limited warranty does not apply if the gas furnace was purch...

Page 12: ... products covered under this warranty No liability shall attach to Warrantor until products have been paid for and then liability shall be limited solely to the purchase price of the equipment under warranty shown to be defective This limited warranty does not apply if the gas furnace was purchased direct i e from internet websites or auctions on an uninstalled basis Additionally this limited warr...