GB
4
MU1H-1111GE23 R0220
1
Safety Guidelines
1.
Follow the installation instructions.
2.
Use the appliance
• according to its intended use
• in good condition
• with due regard to safety and risk of danger.
3.
Note that the appliance is exclusively for use in the
applications detailed in these installation instructions
(see 2 Technical Data). Any other use will not be
considered to comply with requirements and would
invalidate the warranty.
4.
Please take note that any assembly, commissioning,
servicing and adjustment work may only be carried
out by authorized persons.
5.
Immediately rectify any malfunctions which may
influence safety.
2
Technical Data
2.1 F76CS/FN76CS
Note:
The filter is constructed for drinking water installations. In
case of a process water application the filter has to be
proven individually.
2.2 FK76CS/FKN76CS
Note:
The filter is constructed for drinking water installations. In
case of a process water application the filter has to be
proven individually.
3
Options
For Options visit homecomfort.resideo.com/europe
4
Assembly
4.1 Installation Guidelines
•
Install in horizontal or vertical pipework with filter bowl
downwards
– This position ensures optimum filter efficiency
•
Install shut-off valves
•
These filters are armatures which need to be
maintained regularly
•
Ensure good access
– Pressure gauge can be read off easily
– Degree of contamination can be easily seen with
clear filter bowl
– Simplifies maintenance and inspection
•
The installation location should be protected against
frost
•
Fit immediately after water meter
•
Related to the EN 806-2 it is recommended to install
the filter immediately after the water meter
•
In order to avoid flooding, it is recommended to
arrange a permanent, professionally dimensioned
wastewater connection
4.2 Assembly instructions
1.
Thoroughly flush pipework
2.
Install rotatable connector piece
• Note flow direction
• Install without tension or bending stresses
When connecting to an existing flange of another make
ensure that the inlet flow is through the outer ring of
holes. If this is not so, the whole connection piece
must be installed the other way round, even if the
arrow does not then indicate the actual flow direction.
If the flange is threaded, the threaded holes must be
drilled out to a diameter of 6.3 mm.
3.
Install filter with sealing to rotatable connector
4.
Seal in pressure gauges
5.
Set outlet pressure
4.3 Discharge of reverse rinsing water
The reverse rinsing water must be routed to the drain channel
in such a way that no backwater can occur.
To do this there are 3 options:
1.
Direct connection:
Media
Medium: Drinking
water
Connections/Sizes
Connection sizes:
3
/
4
" - 1
1
/
4
"
Pressure values
Operating pressure range:
1.5 - 16 bar
Operating temperatures
Operating temperature range
medium accord. to EN 1567:
5 °C - 30 °C
Specifications
Installation position:
Horizontal or vertical, with
filter bowl downwards
Media
Medium: Drinking
water
Connections/Sizes
Connection sizes:
3
/
4
" - 1
1
/
4
"
Pressure values
Operating pressure range:
1.5 - 16 bar
Max. inlet pressure with clear
filter bowl:
16 bar
Outlet pressure:
1.5 - 6 bar
Operating temperatures
Operating temperature range
medium accord. to EN 1567:
5 °C - 30 °C
Specifications
Installation position:
Horizontal or vertical, with
filter bowl downwards