background image

MU1H-1181GE23 R0

520

4

GB

9.3. Adjusting the setting scale

If the adjustment knob is removed, this setting is lost. A new 
setting can be achieved using a pressure gauge.
1. Close shutoff valve on inlet
2. Close shutoff valve on outlet
3. Release pressure on outlet side (e.g. through water tap)
4. Loosen slotted screw

• Do not remove slotted screw

5. Slowly open shutoff valve on inlet
6. Set desired outlet pressure (e.g. 4 bar)
7. Align scale (e.g. 4) in middle of viewing window
8. Retighten slotted screw
9. Slowly open shutoff valve on outlet

9.4. Cleaning

If necessary, the filter bowl and the filter can be cleaned.

1. Close shutoff valve on inlet
2. Close shutoff valve on outlet
3. Release pressure on outlet side (e.g. through water tap)
4. Unscrew filter bowl

• Use double ring wrench ZR06K

5. Remove filter cartridge
6. Remove filter insert
7. Clean sieve
8. Clean filter bowl
9. Mount the filter insert
10. Re-insert the filter insert
11. Put O-ring on filter bowl
12. Screw filter bowl in place
13. Slowly open shutoff valve on inlet
14. Slowly open shutoff valve on outlet

10. Disposal

• Dezincification resistant brass housing 
• Brass threaded connections
• High-quality synthetic material valve insert
• High-quality synthetic material spring bonnet with adjust-

ment knob and setting scale

• Spring steel adjustment spring
• Stainless steel fine filter
• Red-bronze or shock-resistant, clear transparent synthetic 

material filter bowl

• Fibre-reinforced NBR diaphragm
• Seals
• Brass hose nozzle

Caution !

Do not use any cleaning agents containing solvents 
and/or alcohol to clean the plastic parts!

Frequency: at least every 2 month (depending on local 
operating conditions
• Non-compliance can lead to the filter becoming 

blocked This results in a drop in pressure and 
decreased water flow

• The filter meshes are made of stainless steel. A red 

coating as a consequence of rust from the pipelines 
has no influence on function or the way the filter 
works

To be carried out by an installation company or  the 
operator.

Detergents must not be allowed to enter the environ-
ment or the sewerage system!

Observe the local requirements regarding correct waste 
recycling/disposal!

11. Troubleshooting

Problem

Cause

Remedy

Beating sounds

Filter combination is too large

Call our Technical Customer Services

Water is escaping from the spring 
bonnet

Diaphragm in valve insert is faulty

Replace valve insert

Too little or no water pressure

Shutoff valves upstream or downstream 
from filter not fully open

Open the shutoff valves fully

Filter combination is not set to the 
desired outlet pressure

Set outlet pressure

Filter mesh dirty

Clean or replace filter

Not fitted in flow direction

Fit filter in flow direction (note direction of arrow 
on housing)

The outlet pressure set does not 
remain constant

Filter mesh dirty

Clean or replace filter

Valve insert, sealing ring or edge of 
nozzle is contaminated or worn

Replace valve insert

Rising pressure on outlet (e.g. in boiler) Check check valve, safety group etc.

Summary of Contents for Braukmann miniplus FK06-AABRU

Page 1: ...Installation instructions Keep instructions for later use Filter combination R32347721 001 Rev A Braukmann miniplus FK06 AABRU FK06 AAMBRU...

Page 2: ...wards This position ensures optimum filter efficiency Install shutoff valves before and after the filter Ensure good access Degree of contamination can be seen with clear filter bowl Simplifies mainte...

Page 3: ...valve on outlet 3 Release pressure on outlet side e g through water tap 4 Loosen slotted screw Do not remove slotted screw 5 Slacken tension in compression spring Turn adjustment handle counter clockw...

Page 4: ...tic material filter bowl Fibre reinforced NBR diaphragm Seals Brass hose nozzle Caution Do not use any cleaning agents containing solvents and or alcohol to clean the plastic parts Frequency at least...

Page 5: ...2 AS06 1 2A 8 O ring set for filter bowl pack of 10 1 2 0901246 9 Double ring wrench For removing filter bowl no fig 1 2 ZR06K 10 Hose nozzle no fig BN06 1 4A Spare parts can be purchased separately...

Page 6: ...R0520 6 RUS 1 1 2 3 4 5 2 3 4 5 6 7 7 1 EN 806 2 FK06 AABRU 16 FK06 AAMBRU 16 1 5 6 0 FK06 AABRUBRU max 16 0 bar FK06 AAMBRU max 16 0 bar FK06 AABRU max 40 C FK06 AAMBRU max 70 C 1 2 FK06 AABRU 100 FK...

Page 7: ...7 MU1H 1181GE23 R0520 RUS 7 2 1 2 3 4 7 3 1 2 4 0 15 8 8 1 1 2 3 4 5 6 7 8 9 9 EN 806 5 9 1 9 1 1 1 2 15 9 1 2 1 2 3 9 2 9 2 1 1 2 3 4 ZR06K 5 6 7 8 1 2 25 20 1 2...

Page 8: ...8 MU1H 1181GE23 R0520 RUS 9 10 11 12 13 9 2 2 1 2 3 4 5 6 ZR06K 7 8 9 ZR06K 10 11 12 13 9 3 1 2 3 4 5 6 4 7 4 8 9 9 4 1 2 3 4 ZR06K 5 6 7 8 9 10 11 12 13 14 1 3 2...

Page 9: ...9 MU1H 1181GE23 R0520 RUS 10 NBR 11...

Page 10: ...1 1 2 0901515 2 1 2 D06FA 1 2 3 10 1 2 0901443 4 R1 4 5 S06K 1 4 5 1 2 KF06 1 2A 6 10 1 2 0903127 7 1 2 AS06 1 2A 8 10 1 2 0901246 9 1 2 ZR06K 10 BN06 1 4A 13 RV277 VST06A VST06B M07M bar 6 8 10 4 2 0...

Page 11: ...MU1H 1181GE23 R0520 11 RUS...

Page 12: ...zerland byitsauthorisedrepresentative Ademco 1 GmbH 2020 Resideo Technologies Inc All rights reserved For more information homecomfort resideo com europe Ademco 1 GmbH Hardhofweg 40 74821 MOSBACH GERM...

Page 13: ...MU1H 1181GE23 R0520...

Page 14: ...escription 2 3 Application 2 4 Technical data 2 5 Scope of delivery 2 6 Options 2 7 Assembly 2 8 Commissioning 3 9 Maintenance 3 10 Disposal 4 11 Troubleshooting 4 12 Spare Parts 5 13 Accessories 5 RU...

Reviews: