BATTERY REPLACEMENT
1. At the bottom of the keypad, remove the screw that secures the
front cover to the rear mounting bracket.
2. Remove the batteries, wait 10 seconds, then insert three new 3V
Lithium batteries (see
Specifications
for replacement batteries).
3. Align the case with the cleats and snap into place and secure with
bottom screw
BATTERY CAUTION
: Risk of fire, explosion, and burns. Do not
recharge, disassemble, heat above 55°C, or incinerate. Dispose of used
batteries properly. Keep away from children.
Note
: Constant exposure to high or low temperature or high humidity
may reduce battery life.
PANIC KEYS
This keypad also features panic keys. These keys
may be programmed for Fire, Police, and Medical
alarms. Panic activation requires a 2-button
sequence. After the first button in the sequence is
pressed, you can cancel the panic by pressing any
key other than one of the panic keys.
Panic
There are 3 ways to generate an alarm:
1. Press
Panic
and within 10 seconds press the desired
panic key (
Fire
,
Police
,
Medical
).
2. Press desired panic key and within 10 seconds press
the
Panic
button.
3. Press desired panic key and within 10 seconds press
the same key.
Fire
Police
Medical
KEYPAD PROGRAMMING MODE
This mode displays keypad programmed information and provides access to Default and Reset options. Enter the INSTALLER code +1
to disarm. Press and hold the "3" key for 2 seconds to enter PROGRAMMING mode. The system will exit PROGRAMMING mode after 1
minute of inactivity. Press the "3" key to scroll or "
*
" key to exit.
Display
Meaning/Option
Display
Meaning/Option
App: / Boot:
Displays the keypad’s current App and Boot
versions
Partition= / Keypad ID=
Displays Partition assignment and Keypad ID
programmed in the control panel.
RF6:
Displays the keypad’s SiX software version and
the keypad MAC ID
Reset Keypad
Prompts to Reset Keypad. 2=CONFIRM (restart)
Default Keypad
Prompts to Default Keypad. 2 = CONFIRM to
remove keypad from control panel.
Note:
If the keypad is repowered within 24
hours, it will re-pair with the control panel. After
24 hours, it will need to be re-enrolled.
A: None
(Future Use)
B: None
(Future Use)
SPECIFICATIONS:
Dimensions (mm) / Weight:
161 (H) x 97 (W) x 34 (D) / 285 g
Frequency of Operation:
2.4 GHz
Batteries:
Three (3) - 3V Lithium batteries, Panasonic CR123A/Duracell
DL123A
Tamper:
Wall (audible alert and signal sent to Control Panel)
Sounder:
Piezoelectric
(xxxx-xxxxxx)
www.cnpp.com
www.marque-nf.com
The product should not be disposed of with other household waste. Check for the nearest authorized collection centers or
authorized recyclers. The correct disposal of end-of-life equipment will help prevent potential negative consequences for
the environment and human health.
This system must be checked by a qualified technician at least once every three (3) years.
Any attempt to reverse-engineer this device by decoding proprietary protocols, de-compiling firmware, or any similar actions is strictly prohibited.
REFER TO THE INSTALLATION INSTRUCTIONS FOR THE CONTROL WITH WHICH THIS DEVICE IS USED, FOR DETAILS REGARDING
LIMITATIONS OF THE ENTIRE ALARM SYSTEM.