background image

 

 

BATTERY REPLACEMENT 

1.  At the bottom of the keypad, remove the screw that secures the 

front cover to the rear mounting bracket. 

2.  Remove the batteries, wait 10 seconds, then insert three new 3V 

Lithium batteries (see 

Specifications 

for replacement batteries).  

3.  Align the case with the cleats and snap into place and secure with 

bottom screw

 

BATTERY CAUTION

: Risk of fire, explosion, and burns. Do not 

recharge, disassemble, heat above 55°C, or incinerate. Dispose of used 
batteries properly. Keep away from children. 

Note

: Constant exposure to high or low temperature or high humidity 

may reduce battery life. 

 

 

PANIC KEYS 

This keypad also features panic keys. These keys 
may be programmed for Fire, Police, and Medical 
alarms. Panic activation requires a 2-button 
sequence. After the first button in the sequence is 
pressed, you can cancel the panic by pressing any 
key other than one of the panic keys. 

 

Panic

 

There are 3 ways to generate an alarm: 
1. Press 

Panic

 and within 10 seconds press the desired 

panic key (

Fire

Police

Medical

). 

2.  Press desired panic key and within 10 seconds press 

the 

Panic

 button. 

3.  Press desired panic key and within 10 seconds press 

the same key. 

 

Fire

 

 

Police

 

 

Medical

 

KEYPAD PROGRAMMING MODE

 

This mode displays keypad programmed information and provides access to Default and Reset options. Enter the INSTALLER code +1 
to disarm. Press and hold the "3" key for 2 seconds to enter PROGRAMMING mode. The system will exit PROGRAMMING mode after 1 
minute of inactivity. Press the "3" key to scroll or "

*

" key to exit. 

Display

 

Meaning/Option

 

Display

 

Meaning/Option

 

App: / Boot:

 

Displays the keypad’s current App and Boot 
versions

 

Partition= / Keypad ID=

 

Displays Partition assignment and Keypad ID 
programmed in the control panel.

 

RF6:

 

Displays the keypad’s SiX software version and 
the keypad MAC ID

 

Reset Keypad

 

Prompts to Reset Keypad.  2=CONFIRM (restart)

 

Default Keypad 

Prompts to Default Keypad. 2 = CONFIRM to 
remove keypad from control panel.  

Note:

  If the keypad is repowered within 24 

hours, it will re-pair with the control panel. After 
24 hours, it will need to be re-enrolled. 

A: None

 

(Future Use)

 

B: None

 

(Future Use)

 

 

 

 

SPECIFICATIONS: 

Dimensions (mm) / Weight: 

161 (H) x 97 (W) x 34 (D) / 285 g 

Frequency of Operation: 

2.4 GHz 

Batteries:  

Three (3) - 3V Lithium batteries, Panasonic CR123A/Duracell 

DL123A 

Tamper:  

Wall (audible alert and signal sent to Control Panel)

 

Sounder:  

Piezoelectric

 

 

 

 

 

 

 

 

 

(xxxx-xxxxxx) 

www.cnpp.com

 

www.marque-nf.com

 

 

The product should not be disposed of with other household waste. Check for the nearest authorized collection centers or 
authorized recyclers. The correct disposal of end-of-life equipment will help prevent potential negative consequences for 
the environment and human health.

 

 

This system must be checked by a qualified technician at least once every three (3) years.

 

Any attempt to reverse-engineer this device by decoding proprietary protocols, de-compiling firmware, or any similar actions is strictly prohibited.

 

 

REFER TO THE INSTALLATION INSTRUCTIONS FOR THE CONTROL WITH WHICH THIS DEVICE IS USED, FOR DETAILS REGARDING 
LIMITATIONS OF THE ENTIRE ALARM SYSTEM. 

Summary of Contents for PROSIXLCDKP-EU Series

Page 1: ...ocal Programming key 2 second hold MAX Arm Maximum key No Delay TEST System Test key BYPASS Bypass Zone key INSTANT Arm Instant key No Delay CODE Add Security Codes key CHIME Chime Mode key READY Check Zones key Quick Arm key Disarm Cancel Key Panic Alarm key Fire Panic key Police Panic key Medical Panic key Keys 0 9 Numeric keys used to enter security code s Prox Tag reader RFID KEYPAD OPERATION ...

Page 2: ...t can be used Registration and programming are conducted through the AlarmNet 360 cloud based management platform using the Resideo Pro App After accessing the customer account perform the following steps 1 From the Select KEYPADS 2 Select ADD KEYPAD 3 Select Learn and wait for the Control Panel to be in learning mode 4 Activate the keypad by pressing any key The keypad automatically attempts to p...

Page 3: ...OGRAMMING mode after 1 minute of inactivity Press the 3 key to scroll or key to exit Display Meaning Option Display Meaning Option App Boot Displays the keypad s current App and Boot versions Partition Keypad ID Displays Partition assignment and Keypad ID programmed in the control panel RF6 Displays the keypad s SiX software version and the keypad MAC ID Reset Keypad Prompts to Reset Keypad 2 CONF...