© RESOL 11089 deltasol_c2.monen.ind
d
|
6
D e lt a S o l
®
C2
1
2
3
backwards
SET
(selection/adjust-
ment mode)
2.
Operation and function
2.1
Commissioning and buttons for
adjustment
Connect the controller to the mains. The controller is in
an initialisation phase. After this phase, the controller is in
automatic operation with factory settings.
The controller is then ready for operation and normally the
factory settings will give close to optimum operation.
The controller is operated via the 3 push buttons below
the display. The forward-button (1) is used for scrolling
forward through the menu or to increase the adjustment
values. The backward-button (2) is similarly used for scroll-
ing backwards and reducing values.
In order to access the adjustment mode, scroll down in the
display menu and press the forward button (1) for approx.
2 seconds after you have reached the last display item. If
an adjustment value is shown on the display, the
icon
is displayed. Now, you can access the adjustment mode by
using button 3.
— Press buttons 1 and 2 in order to select a channel
— Briefly press button 3,
appears (flashing) (
-mode)
— Adjust the requested value by pressing the buttons 1 and 2
— Briefly press button 3, so that
permanently appears,
the adjusted value will be saved.
forwards
The system monitoring display consists of 3 ranges: The
channel display
, the
toolbar
and the
system-screen
(active arrangement).
The
channel display
consists of 2 lines. The upper line is an
alpha-numeric 16-segment display (text display) for display-
ing channel names and menu items. In the lower 7-segment
display, the channel values and the adjustment parameters
are displayed.
Temperatures and temperature differences are indicated
in or .
2.2.1 Channel display
Channel display
2.2.2 Toolbar
The additional symbols in the
toolbar
indicate the actual
system status.
toolbar
2.2
System-Monitoring display
Monitoring-Display
Symbol normal
flashing
relay 1 active
store maximum limitation active
/ maximum store temperature
exceeded
collector cooling function active
recooling function active
antifreeze function active
collector minimum limitation
active
antifreeze function active
Kollektornotabschaltung aktiv
oder Speichernotabschaltung
+
sensor fault
+
manual mode
change of adjustment channel
SET-mode