System Operation
A single-click of the BITE button changes the display to the diagnostic BITE
screen. Status information text is presented in three colors:
White/Green: Normal
operation
Yellow:
Out of compliance/calibration
Red:
Malfunction
If a red indication is shown in the Receiver Gain or Phase Offset box, place the
cursor on the item shown in red, and the receiver number and associated offset
will be shown under the lower left corner of the selected box. As problem areas
are corrected, the BITE button will change to green, assuming all other functions
are working properly. Click the BITE button again to return to the sonar display.
Figure 15, BITE Diagnostic System Information
NOTE
The four Operation menus, plus OFF, available at the Main Display are available
in the BITE screen as well. Click on MENU to cycle through the menu selections.
In addition, the sonar data wedge is displayed to allow the operator to monitor
sonar operation while changing an item on either the Configuration or Modes
menu.
______________________________________________________________________
SeaBat 8101 Operator's Manual
3-17
Version 3.02