The Tinnitus Sound Generator (TSG) is designed as a 

sound therapy tool for tinnitus management. The TSG 

features are the same in all technology levels, and can 

be activated in any program.

Notes:

• 

The TSG volume slider is in dBSPL.  

• 

The TSG settings overlayed on the audiogram can be 
displayed in dBSPL or dBHL. 

• 

The binaural link option is not available for all features in 
TSG. Only Amplitude Modulation, Modulation Speed and 
Volume Control can be linked during the fitting. 

• 

For a TSG only program ensure the HI Microphone 
option is turned ‘Off’. 

 

1.  Activate the TSG

•  Select the program you want to activate the TSG in. 

•  Select the menu option in the upper right corner.  

(Figure 1) 

•  Under the Fitting heading, select Tinnitus Sound 

Generator. (Figure 1) 

•  Turn the Tinnitus Sound Generator slider to ‘On’.  

(Figure 2)

Figure 1:

Figure 2:

2.  Set the TSG volume

The volume of the TSG is set using the volume slider. The 
volume should be set to a level that provides relief, but does 
not completely mask the tinnitus. (Figure 3)

Note

: The volume slider is in dBSPL.

Below is a suggestion on how to first fit the TSG. It uses 
the threshold of audibility as a starting point. 

Find the TSG threshold of audibility (three steps)

•  Using the volume slider, turn up the volume until the 

patient reports that they can just barely hear the TSG 
white noise. This is the TSG threshold of audibility. 

•  Increase the volume slider until the patient reports 

they can no longer hear their tinnitus over the TSG 
sound. This is the level at which their tinnitus is com-
pletely masked. This is the minimum masking level 
(MML).

•  Set the volume 5–10 dB above the threshold level. 

(You can go higher than 10 dB if necessary, but do not 
completely mask the tinnitus signal. This is where the 
MML is important) 

3.  Set the TSG bandwidth

•  Our TSG defaults to a broadband white noise setting. 

There are 4 sound preset options to choose from. They 
can be customized using the Range option to adjust the 
frequency shaping. (Figure 4) 

4.  Customize the TSG features according to patient 

preference

•  Amplitude Modulation can be activated if the patient 

finds it to be comfortable. (Figure 5)

•  Amplitude Modulation causes the TSG to fluctuate in 

volume, creating an “ocean-like” noise sequence. A Mild 
setting offers less fluctuation, whereas a Strong setting 
offers more fluctuation.

•  Modulation Speed controls how quickly the volume 

fluctuations occur. A Slow setting allows more time 
between fluctuations, whereas a Fast setting allows 
less time between fluctuations. (Figure 5)

•  Selecting ‘Synchronize’ will enable ear-to-ear 

commu nication, ensuring the features of the TSG are 
automatically functioning symmetrically. (Figure 6) 

5.  Customize the Volume Control options

•  The Volume Control options determine how the  

volume of the TSG will be controlled. (Figure 7)

•  Selecting ‘Volume Control’ will reassign the function 

of the manual volume control to the TSG only for that 
program.

•  Selecting ‘Environmental Steering’ will allow the volume 

of the sound generator to automatically adapt to the 
listening environment, ensuring comfort in all situations.

•  Selecting ‘Volume C Environmental Steering’ 

will combine the use of these two features. It allows 
manual volume adjustments while the Environmental 
Steering features is also active.

Figure 3:

Figure 4:

Figure 5:

Figure 6:

Figure 7:

TSG fitting guide

ReSound Smart Fit

TM

Summary of Contents for LINX 3D

Page 1: ...ReSound LiNX 3D fitting guide A guide for professionals...

Page 2: ...software supports all ReSound LiNX 3D hearing instruments Prior to connecting to ReSound Smart Fit ReSound hearing instruments require fresh batteries when fitting Remove the stickers from the batter...

Page 3: ...nue 1 Smart Launcher Both ReSound Aventa and ReSound Smart Fit are contained within one software installation The Smart Launcher will detect both ReSound LiNX 3D and legacy instruments and then retrie...

Page 4: ...ams Program tools can be found in the tab on the far right 4 Click Save to save the fitting to the hearing instruments and database 1 3 2 4 Patient Profile Screen 1 Select the Patient Experience Level...

Page 5: ...al Directionality II The Focus directional ear and Monitor omnidirectional ear are prescribed based on the audiogram and any speech audiometry data that may be available Spatial Sense An omnidirection...

Page 6: ...peech in Noise or Loud Speech in Noise This maintains the settings for other environments allowing for fitting precision and personalization Alternately the Mild Moderate Considerable and Strong setti...

Page 7: ...eminder to deactivate the connection with the smart device Wired fittings Ensure that the programming interface Speedlink Hi PRO USB or NOAHlink is connected to the fitting computer before launching R...

Page 8: ...ue in the lower right corner of the screen once the hearing instruments are selected and assigned 6 The connection flow will continue Follow the steps in the First Fitting section of this guide Replac...

Page 9: ...ides an overview of how to perform a remote fine tuning adjustment with ReSound Smart Fit fitting software and the ReSound Smart 3D app A ReSound LiNX 3D 961 DRW wireless binaural fitting is used as t...

Page 10: ...icon for GN Online Services 3 Click and drag the cloud icon to the taskbar 4 The cloud icon will now appear in the taskbar as shown 1 2 3 4 Activate Consent 1 Click Start Consent 2 Click Agree on eac...

Page 11: ...onnaire which will appear after Message from patient in the Assistance Request on the Timeline This will expand the questionnaire for viewing 1 2 4 3 2 1 Notification of Assistance Request 1 The numbe...

Page 12: ...s Click the On toggle for View Patient Settings at the bottom right of the Fitting screen This will enable viewing of the patient s preferred settings in the app 1 In the Gain Adjustments screen the p...

Page 13: ...imum of five open requests in the ReSound Smart 3D app Only the hearing care professional can close them 1 Go to the Assistance Request on the patient s timeline 2 Click on Actions to select the optio...

Page 14: ...el MML Set the volume 5 10 dB above the threshold level You can go higher than 10 dB if necessary but do not completely mask the tinnitus signal This is where the MML is important 3 Set the TSG bandwi...

Page 15: ...logos are registered trademarks owned by the Bluetooth SIG Inc MK604805 Rev E 2018 03 ReSound Government Services 8001 E Bloomington Freeway Bloomington MN 55420 USA 1 800 392 9932 resound com govern...

Reviews: