Installation
A
.
B
. T
urn OFF power
to the
f
urnace
or
a
ir
h
a
ndler
.
C
.
or
a
ir
h
a
ndler
T
he CG 95 1
" E
lectronic
Air
Cle
a
ner
requires
Step 1
24V
AC to oper
a
te
. T
his power
is best
supplied with
a separate, dedicated 24VAC transformer.
Dedicated Transformer
20/40VA Transformer
CAUTION
!
Be sure to connect to a certified, thermically protected,
Class II power transformer with 24Vac, 60Hz, 5VA min.
WARNING!
to
heed them
c
a
n result
in serious in
j
ury
or
de
a
th
.
CAUTION!
F
a
ilure
to heed them
c
a
n result
in in
j
ury
or
m
a
teri
a
l
property
dam
a
ge
.
WARNING
!
E
lectric
a
l wiring
should only
be
per
f
ormed by
a
qualified technician.
Installation
Step 2
2a)
2b)
For the separate 24VAC transformer there are two op�ons.
A second op�on is to connect the 120 to 24VAC transformer
to a 120 line voltage terminal on the circuit board. This will
typically be a constant on connec�on.
If the circuit board has an “EAC” (Electronic air cleaner)
terminal you can connect there. This circuit is connected
to the fan & will ac�vate the air cleaner when the fan circuit
is on. The EAC terminal is usually 120 volt however do
confirm this with a volt meter or the circuit board electrical
specifica�ons.
Running the Power Cord
It may be necessary to run the power cord through the
cabinet of the furnace or air handler to reach the filter
rack area. If so:
Drill a suitably sized access hole in the cabinet to run
the power cord through...or...run the cord through
one of the rubber plugs on the side of the furnace
or air handler.
Insert the supplied grommet if an access hole(9/32”)
was drilled. This will protect the insula�on of the power
cord from being cut or damaged.
Do not crimp or abrade the cord.
a.
b.
c.
d.
equipment, including the blower of the furnace or air
Ensure the power cord is kept away from any rota�ng
handler
.
Step 3)
Rubber Access Plug
9/32”
Hole
OR