Check the medication nebulizer cup for 
damage. (The nebulizer cup enclosed 
with your Inspiration Elite should be 
replaced regularly. Ask your healthcare 
provider for replacement guidelines and 
supplies).
Place your Inspiration Elite unit on a 
firm, flat surface near an electrical outlet 
and in an area where you can be seated 
comfortably during your treatment.
Plug the power cord into the electrical 
socket.
Do not operate the unit without the filter 
or with a clogged (dirty) filter. Operating 
the unit with a dirty filter can impair 
proper operation and cause damage that 
is not covered by the warranty.
Wash your hands before preparing your 
medication.
Assemble your nebulizer cup and add 
your prescribed medicine following your 
prescription and the separate nebulizer 
instructions.
Connect one end of the tubing to the 
bottom of the cup and the other end of 
the tubing to the air outlet on the unit.
Turn the power switch on (

I

) to begin 

your treatment.
When your treatment is complete, turn 
the power switch off (

O

) and unplug the 

unit.
Clean the medication nebulizer cup 
according to its instructions.

1

2

3

How to use your 
Inspiration Elite

4

Care and cleaning

5

6

7

8

9

10

l

 

Unplug the unit before cleaning.

l

 

Use a damp cloth to wipe down the outside of the 
compressor at least once each month (or more if 
necessary).

l

 

Check the filter at least once each week. Replace 
the filter when dirty. Replacement filters are 
available where you purchased this product. 

l

 

Pack of 4: Part No. 1054388

l

 

To change the filter:

l

 

Lift up the filter and remove it by twisting and 
pulling it straight up.

l

 

The filter should be replaced when it becomes 
discoloured. Do not wash or reuse the filter.

l

 

After each cleaning, check that the unit is working 
properly by verifying that air still comes out of the 
nozzle when the unit is turned to the 

ON

 position.

l

 

The unit is oil-free. Do not lubricate.

l

 

Service should only be performed by an authorised 
dealer. Unauthorised repair voids warranty.

KEEP THESE INSTRUCTIONS FOR FUTURE USE

 

Glossary of symbols

 

Caution: check the operating instructions

 

Follow operating instructions

~

 

Alternating current 

RH

 

Relative humidity

P

 

Atmospheric pressure 

I/O

 

Switch ON/Switch OFF

 

Class II unit

 

Type B

 

Temperature limitations

 

Separate collection

0123

This device meets 93/42/EEC directive.

12049_RIUK_InspirationEliteInstPAGES_SEUROPE_1054391_REV2_v1.indd   2

26/10/09   15:33:19

Summary of Contents for Inspiration Elite

Page 1: ...ÁVOD NA POUŽITIE rozprašovacieho kompresorového systému Inspiration Elite NAVODILA za sistem kompresorja in nebulizatorja Inspiration Elite Аэрозольный аппарат Inspiration Elite с компрессором ИНСТРУКЦИИ www respironics com 2009 Respironics Inc and its affiliates ALL RIGHTS RESERVED Respironics and Inspiration Elite are trademarks of Respironics Inc or companies within the group respectively regis...

Page 2: ...e Nebulizer Compressor System Inspiration Elite is an electrical mains powered air compressor nebulizer system intended to provide a source of compressed air for medical purposes for use in home healthcare It is to be used with a pneumatic nebulizer to produce aerosol particles of medication for respiratory therapy for both children and adults Diagram B shows the parts included with the system Sid...

Page 3: ...fallen into water Unplug immediately Caution To reduce the risk of burns electrocution fire or injury to persons l This device should only be used on the advice of a physician l This product should never be left unattended when plugged in l Close supervision is necessary when this product is used by on or near children or physically challenged individuals l Use this product only for its intended u...

Page 4: ...instructions 1 2 3 How to use your Inspiration Elite 4 Care and cleaning 5 6 7 8 9 10 l Unplug the unit before cleaning l Use a damp cloth to wipe down the outside of the compressor at least once each month or more if necessary l Check the filter at least once each week Replace the filter when dirty Replacement filters are available where you purchased this product l Pack of 4 Part No 1054388 l To...

Page 5: ...essor to be free from defects in materials and workmanship under normal use and operation for a period of 3 years from date of purchase from Respironics Inc The warranty is limited to repair or replacement at Respironics Inc s sole option of any such component or equipment claimed to be defective when claim is shown to be bona fide by evaluation by Respironics Inc This warranty does not extend to ...

Reviews: