batter
y(ies) as required turn the Solar Siren back to
Disarmed Mode.
Note: When r
eplacing PIR batteries, fit PP3 Alkaline
type. Rechargeable batteries should NOT be fitted.
MAINTENANCE
Y
our Wirefree Alarm System requires very little
maintenance. However, a few simple tasks will ensure its
continued reliability and operation.
SOLAR SIREN
1.
At least once a year, preferably in the Autumn, the
solar panel on the top of the siren housing should be
cleaned using a soft, damp cloth. This operation will
ensure that the solar panel receives all the available
light. The cleaning operation can be combined with
the general cleaning of the outside of the house,
windows etc. to reduce maintenance time.
2. Should you, for any reason, have to completely power-
down the Solar Siren (eg. to move the system to a new
premises) turn the Solar Siren to Service mode,
disconnect the rechargeable battery and initial power-
up battery and ensure that the solar panel is covered
with a light proof material to prevent it being energised.
3. The Solar Siren should not be left for long periods
with the batteries connected, unless the unit is able
to receive sufficient light to maintain the battery
charging circuit. Failure to maintain charge to the unit
will result in the rechargeable battery running
unacceptably low. Should this occur, the unit must
be recharged from a 240/7.5 Volt DC 100mA mains
adaptor (Response order code Solar S100TR). When
re-powering the Solar Siren fit a new 9 Volt PP3 leak
proof Alkaline initial power-up battery to ensure that
the Unit receives sufficient power until the solar panel
can recharge the main battery completely.
4. The main rechargeable battery has a typical life of 3-4
years and needs no maintenance during this period,
providing the battery is kept charged. The battery will
be damaged if it is stored in a discharged state.
The rechargeable battery should be
taken to a suitable Recycling Centre at
the end of its useful life. DO NOT
dispose of with your normal household
waste. The rechargeable battery contains Sulphuric
Acid - DO NOT attempt to open the casing.
DETECTORS & REMOTE CONTROL
The Detectors and Remote Contr
ol(s) require no
maintenance. Simply replace the batteries once a year or
when a low battery is indicated. The specifications for
the Detector and Remote Control batteries are as follows:
PIR Movement Detectors:
9 Volt PP3 Alkaline
Remote Controls:
12 Volt 23A Alkaline
Optional Magnetic 2 x 3 Volt 230mAhr Lithium Cells
Contact Detectors:
(Panasonic CR2032 or equivalent)
Please recycle used batteries where Local Authority
facilities exist. Keep batteries away from children
and do not dispose of in fire.
ENTR
Y/EXIT DELAY OPTION
In addition to the standar
d Instant alarm operation;
the Solar Siren incorporates the facility to give a 15
second Entry/Exit Delay time when used in conjunction
with the optional Wireless Security Keypad CA2000KP.
It is not possible to programme an Entry/Exit Delay
using only the Remote Control.
When armed using the optional Keypad, the Solar
Siren will give one bleep followed by a 15 second
Exit Delay; followed by one bleep. The system will
then be fully armed. If any detector is then triggered,
the system will initiate a 15 second Entry Delay. The
Solar Siren will emit one long bleep followed by a
15 second Entry time during which the system
should be disarmed via the Keypad or a Remote
Control from the system. If the system is not
disarmed a full alarm condition will occur at the end
of the 15 second Entry Delay period.
USING THE OPTIONAL SECURITY
KEYPAD:-
Full installation and operating instr
uctions are
included with the CA2000KP optional Wirefree
Security Keypad.
10
Eclipse E100
Pb
Arms system
with 15 second
Entry/Exit Delay
Access Code
?
?
?
?
ON
Access Code
?
?
?
?
OFF
Disarms system