background image

ACCESSORIES

12

Eclipse E100

EXTENDING YOUR E100 WIREFREE ALARM SYSTEM

Y

ou may add Wirefree Magnetic Contact Detectors and additional Wirefree PIR Detectors etc. from the CA2000

range of accessories as required, to give additional protection where needed.  The following accessories are also

available to extend and enhance your system.

E100D

STROBE UPGRADE

(This part only)

CA2000STR

CA2000M

OFF

1

3

2

4

ON

CA2000KP

STROBE UPGRADE
CA2000STR

Add to your existing Sir

en Unit to give full Siren & Strobe protection.

The Strobe Flash Light is activated simultaneously with your siren

which will help identify a house in alarm condition.

DUMMY SIREN E100D

The Sir

en is available as a dummy design and acts as an excellent

visual deterrent.

WIREFREE MAGNETIC CONT

ACT DETECTOR

CA2000M

Pr

otect opening doors and windows using this slimline Wirefree

Magnetic Contact Detector.  Simple to install on most doors and

windows using the double sided adhesive pads or screws supplied.

The detector senses when the magnet moves away from the side of

the detector and sends a coded radio signal to the Solar Siren to

initiate an alarm. 

Supplied complete with 2 x 3 Volt Lithium batteries.

WIREFREE SECURITY KEYP

AD CA2000KP

This small batter

y operated keypad requires no wiring and is fitted in

minutes.  It sends security coded radio signals to your Siren and only

allows access to those who know your user changeable access code. 

Designed for installation inside the property 

the Keypad allows you

to set a 15 second Entry/Exit Delay on your system for greater

flexibility. 

The ideal location for the Keypad is nor

mally adjacent to

the main entrance door for easy access when entering or leaving the

premises.  Supplied complete with 9 Volt alkaline battery.

Summary of Contents for E100 Wirefree

Page 1: ...Installation Operating Manual E100 Wirefree Alarm System ...

Page 2: ...IMPORTANT NOTE All components with the exception of the External Solar Siren are only suitable for internal use SYSTEM SECURITY This system has been designed to both detect intruders and act as a strong deterrent to would be intruders Please remember that given adequate knowledge and time it is possible to overcome any alarm system and we therefore recommend that an Intruder Alarm is used in conju...

Page 3: ...refree Passive Infra Red Movement Detectors PlR s or Wirefree Magnetic Contact Detectors either at the time of initial installation or at a future date You may also wish to purchase additional Remote Control Units for use by other members of your household or a Wirefree Security Keypad to give a timed Entry Exit Delay Full details of other accessories to extend your system are given on page 12 Ecl...

Page 4: ...ING AND EXTENDING YOUR WIREFREE ALARM SYSTEM 2 Eclipse E100 PLANNING YOUR INSTALLATION Before attempting to install your Wirefree Alarm System it is important to study your security requirements and plan your installation Each property will have its own layout the diagrams shown are intended only as a guide External Solar Siren Magnetic Contact Detector Magnetic Contact Detector PIR Remote Control...

Page 5: ...t by neighbouring walls trees and roof overhangs should also be avoided In practice the Solar Siren should be positioned a minimum of twice the width of the eaves overhang below the eaves Remember that in winter the sun is lower in the sky and you should avoid winter shadows where possible The External Solar Siren contains a sophisticated radio receiver However reception of radio signals can be af...

Page 6: ... unit should not be repeatedly set into alarm during installation testing as this could rapidly drain the battery Hinge the front cover locating tabs over the top edge of the back plate push the base of the siren cover into place and secure with the holding screw IMPORTANT Ensure that the rear tamper switch is closed when you fit the siren cover to the back plate eg listen for the switch to click ...

Page 7: ...sing the OFF button on the Remote Control SETTING UP THE REMOTE CONTROL 12 VOLT BATTERY Remove the cover with a coin and insert the battery with the negative towards the battery spring HOUSE CODE Inside you will find a row of 8 dip switches 1 8 This is your House Code Set these switches to the same combination of ON and OFF as the dip switches in the Solar Siren Replace the battery cover Stand wit...

Page 8: ...Red Movement Detectors If this is not possible alternative mounting arrangements may be required 4 Where possible mount the detector so that the logical path of an intruder would cut across the fan patterns rather than directly towards the detector Any number of PIR Movement Detectors can be used with your system providing they are all coded with the System House Code and are within the radio rang...

Page 9: ... Where Two Pulse Count Detection has been selected the LED will be dim on first detection and brighter on the second 2 By walking into the protected area the detector will now be triggered each time the detector senses movement and the LED will flash If necessary re adjust the detection distance by angling the detector up or down on its wall bracket 3 Replace the battery cover on the detector Note...

Page 10: ...second and then extinguish each time the Magnet is parted from the Detector TESTING THE SYSTEM A INITIAL TESTING Set the Solar Siren into Disarmed mode by pressing and holding the ON button on the Remote Control for approximately 10 seconds until the Solar Siren acknowledges the signal by emitting one long bleep Note only required on initial testing or if the Siren is in Service mode B START OF TE...

Page 11: ...his process can be repeated up to three times If a full alarm condition is initiated accidently the alarm can be stopped immediately by pressing and releasing the OFF button on the Remote Control SYSTEM SERVICE MODE To prevent the alarm from being activated when either opening the Solar Siren or removing a battery cover from a detector it is necessary to first turn the Solar Siren to Service mode ...

Page 12: ... The battery will be damaged if it is stored in a discharged state The rechargeable battery should be taken to a suitable Recycling Centre at the end of its useful life DO NOT dispose of with your normal household waste The rechargeable battery contains Sulphuric Acid DO NOT attempt to open the casing DETECTORS REMOTE CONTROL The Detectors and Remote Control s require no maintenance Simply replace...

Page 13: ...rectly 4 Allow up to one minute for detector to settle down 5 Ensure that detector is mounted the correct way up battery compartment at the bottom except for Pet Alley 6 Ensure that the detector is mounted at the correct height 2 2 5m from floor except Pet Alley 7 Check that the detector is correctly set up See setting the PIR Movement Detectors page 7 8 If detector is mounted upside down for Pet ...

Page 14: ...CA2000M Protect opening doors and windows using this slimline Wirefree Magnetic Contact Detector Simple to install on most doors and windows using the double sided adhesive pads or screws supplied The detector senses when the magnet moves away from the side of the detector and sends a coded radio signal to the Solar Siren to initiate an alarm Supplied complete with 2 x 3 Volt Lithium batteries WIR...

Page 15: ... a fault please call the Helpline on the above number Should you need to return a product it must be to the address below in adequate packaging with 1 A copy of your original invoice receipt 2 A full description of the fault 3 All relevant batteries NOTE If returning a system make sure that all batteries are disconnected and secure and that the unit is adequately packaged to prevent damage in tran...

Page 16: ...r digit access code On Air indicator 15 second Entry Exit Delay facility Anti tamper Indoor use only Dual Personal Attack buttons Low battery indicator Alkaline battery supplied Wirefree Security Keypad Optional LED battery confirmation Anti tamper Operating gap 5mm Door or window mounting Lithium batteries supplied Wirefree Magnetic Contact Detector Optional Instant ON OFF Personal attack button ...

Reviews: