40
ENGLISH
GB
Fuse replacement and thermal relay rearm
The fuses (
A
) and the thermal relay (
B
) are
in the upper part of the blast chiller. To access
these just open the control panel (
C
) by loosening
the two screws positioned in the lower part of the
control panel and rotating it upwards. After
opening, make sure that it does not fall back
down.
U.V. Lamp Replacement
To access the evaporator proceed as follows:
1.
Open the door (
A
) of the appliance.
2.
Remove the runners (
B
):
3.
Loosen the two screws (
C
) on the front of the
deflector.
4.
Turn the deflector (
D
) to the right.
Once the deflector is turned, it is possible to
switch the UV lamp on. That lamp can be
removed turning it (
E
). Carry out all the operations
in reverse order after having removed the U lamp.
6.4.
Extraordinary Maintenance 10TR
Have the following operations carried out
periodically
by specialised staff:
Check the perfect sealing of the door
gaskets and replace them if necessary.
Check that the electric connections have
not loosened.
Check the efficiency of the heating
element resistance
Check functioning of the board and
probes.
Check the efficiency of the electrical
system.
Clean the evaporator.
Clean the condenser.
B
D
C
B
A
E
B
C
A
Rearm the thermal relay
using the grey button