background image

1

FIT ADAPTOR PLATE TO 

AQUASTAR NICHE USING 

EXISTING SCREWS

CONNECT 

CABLE AS PER 

EMRX 

INSTRUCTION 

MANUAL

EMRX-AQUASTAR

SERIES

RX

EM

INSTALLATION GUIDE

FOR ASSISTANCE PLEASE 

CONTACT 

SPA ELECTRICS 

ph: +61 3 9793 2299

info@spaelectrics.com.au

www.spaelectrics.com.au

1

2

READ THIS FIRST

INSTALLATION

INSTALLATION 

ADAPTOR INSTALLATION

ALIGN RED 

BUTTON WITH 

‘TOP’ MARKING 

ON ADAPTOR TO 

ENGAGE IN 

BAYONET LOCK 

ROTATE LIGHT 

CLOCKWISE TO 

LOCK INTO 

POSITION

LIGHT INSTALLATION

2

1

BEFORE YOU START

Ensure pool lights are turned off and system is isolated. 

Confirm existing transformer is a 

12v AC ONLY,

  magnetic type safety isolating transformer and is in good working order (if in doubt contact Spa Electrics 

or your prefered registered electrician). 

Installation of the EMRX Light requires connection to a 

low voltage circuit 

(12v AC)

 ONLY

. No work should be carried out on mains voltage (240v) systems 

unless done so by a registered electrician in accordance with AS/NZS 3000:2007 (current amendment) standards.  

For safe and proper installation, ensure that only those parts supplied with the system are used. 

Check that there is enough cable behind the existing light to allow for cable connection above water. If enough cable is not availabe, water level must be 

lowered to connect EMRX light.

Ensure pool light cable is circular and free of damage or imperfections i.e. cuts, cracks or deformation. 

If possible, trim cable back until a fresh end of cable is available.

This manual is to be used in conjuction with the supplied EMRX installation manual. 

For any further information please contact Spa Electrics (03) 9793 2299

Reviews: