background image

This device complies with part 15 of the FCC rules. Operation is subject to the following two (2) conditions:

(1)

  This device may not cause harmful interference, and

(2)

  this device must accept any interference received, including interference that may cause undesired 

operation.

Note: 

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant 

to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful 

interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy 

and, if not installed and used in accordance with the instructions, may cause harmful interference to radio 

communications. However, there is no guarantee that interference will not occur in a particular installation. 

If this equipment does cause harmful interference to radio or television reception, which can be determined 

by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more 

of the following measures:

• 

Reorient or relocate the receiving antenna.

• 

Increase the separation between the equipment and receiver.

• 

Connect the equipment into an outlet on a circuit different to that to which the receiver is connected.

• 

Consult the dealer or an experienced radio / TV technician for help.

Do not make any changes or modifications to the equipment unless otherwise specified in the manual.

FCC COMPLIANCE STATEMENT

ELECTRICAL GROUNDING

AQUA/LAMP® is registered trademark of Consolidated Pool & Spa Industries Inc Canada. 

Spa Electrics Export Pty Ltd Australia and it’s ATOM and RETRO brands are not affiliated or endorsed by these companies and/or their brands.  

Underwriters Laboratories (UL) Statement

Per the NEC, NFPA 70, Article 680.23 (B)(5), states that bonding shall not be required 

for luminaires that are listed for the application and have no non-current carrying metal 

parts. In addition, per Article 680.26 (B)(4), exception states that Listed low-voltage 

lighting systems with non-metallic forming shells shall not require bonding. 

Therefore, luminaires with polymeric/non-current carrying metal parts 

are not required to be grounded / bonded.

Manufacturers Statement

Spa Electrics ATOM & QUANTUM (EM & WN9) luminaires with their plastic housing 

designs and plastic niches do not require grounding / bonding.

Spa Electrics ATOM & QUANTUM (EM & WN9) lights have also been determined 

to comply with the applicable requirements for wet-niche, LED type Swimming Pool 

and Spa Luminaires.

13

Summary of Contents for EMRX

Page 1: ...AQUA LAMP POOL LIGHTS Replaces existing ...

Page 2: ...ctrics com www selectpoolproducts ca Tel 1 855 881 0889 Email info selectpoolproducts ca 1 READ THIS FIRST PRODUCT WARNINGS TOOLS REQUIRED WINTERIZATION INCLUDED PARTS BEFORE YOU START EXISTING LIGHT REMOVAL CABLE PREPERATION CABLE JOINER INSTALLATION LIGHT INSTALLATION LIGHT REMOVAL WINTERIZATION ELECTRICAL GROUNDING FCC COMPLIANCE ...

Page 3: ...ny user serviceable parts opening the light head will void the product warranty Pool chemicals pH levels Due to the corrosive nature of unbalanced pool chemicals Spa Electrics strongly recommends that your pool water is balanced prior to installing your pool Lights or any plastic or stainless steel components and tested weekly to maintain these levels pH levels should be maintained between 7 2 7 6...

Page 4: ...r illustrative purposes only Appearances of parts and assemblies may vary from the enclosed illustrations Please contact your reseller if you have any questions regarding the correct installation of this product IMPORTANT NOTES WINTERIZATION Lights must be removed from pool wall and cable disconnected via plug stored in a dry and safe place Cable joiner should remain connected Red Terminal Cover m...

Page 5: ... X RETRO LIGHT PLUG CONNECTION UNDERWATER CABLE JOINER INCLUDED PARTS ADAPTOR PLATE To suit existing AQUA LAMP SCREW DRIVER WRENCH 18 OF 18AWG CABLE 24 29 PREASSEMBLED TERMINAL COVER FOR WINTERIZATION 4 ...

Page 6: ...E MIN 15 WATT PER LIGHT IN GOOD WORKING ORDER DC OR LED DRIVER ELECTRONIC OR SWITCH MODE WEATHER DAMAGED OR IN OTHERWISE POOR CONDITION 12V AC POWER SUPPLY POWER SOURCE INTENDED FOR SWIMMING POOL USE ENSURE SYSTEM IS SAFELY ISOLATED DURING THE INSTALLATION PROCESS IF IN DOUBT CONTACT YOUR ELECTRICAL CONTRACTOR FOR ASSISTANCE 5 ...

Page 7: ...CLOCKWISE DISCONNECT CABLE TO EXISTING POOL LIGHT ENSURING ENOUGH CABLE LENGTH REMAINS IN THE NICHE ABOVE THE NOMINAL WATER LEVEL TO ENSURE SERVICE ACCESS 1 1 2 STRIP CABLE OUTER AND INNER SHEATHS TO THE BELOW LENGTH 1 REMOVE EXISTING LIGHT 2 PREPARING EXISTING CABLE 10mm EXISTING CABLE 10mm NICHE LIGHT 1 2 6 ...

Page 8: ...SING 29mm WRENCH PLACE CABLE GLAND NUT AND THREADED HEX NUT OVER RETRO LIGHT CABLE INSTALLING CABLE JOINER 1 OPEN CABLE JOINER 2 CONNECT RETRO LIGHT CABLE 1 1 2 2 24mm RETRO LIGHT EXISTING CABLE 29mm IMPORTANT CONNECT WIRES TO TERMINAL BLOCK USING FLAT BLADE SCREW DRIVER 7 ...

Page 9: ...LING CABLE JOINER SLIDE THREADED HEX NUT OVER TERMINAL BLOCK ENSURING CABLE SHEATH EXTENDS INSIDE THE ASSEMBLY 3 TIGHTEN CABLE GLAND NUT USING 24mm WRENCH 4 ATTACH MAIN BODY AND TIGHTEN USING 29mm WRENCH 5 8 ...

Page 10: ...EADED HEX NUT OVER TERMINAL BLOCK AND TIGHTEN ONTO MAIN BODY USING 29mm WRENCH PLACE CABLE GLAND NUT AND THREADED HEX NUT OVER EXISTING LIGHT CABLE 1 1 2 3 TIGHTEN CABLE GLAND NUT USING 29mm WRENCH 4 2 CONNECT WIRES TO TERMINAL BLOCK USING FLAT BLADE SCREW DRIVER 9 ...

Page 11: ...N 1 COIL CABLE INTO NICHE 2 ATTACH LIGHT FITTING TO NICHE ALIGN ADAPTOR PLATE WITH EXISTING MOUNTING TABS 1 1 2 TWIST LIGHT ASSEMBLY INCLUDING ADAPTER PLATE CLOCKWISE TO ENGAGE MOUNTING TABS AND LOCK INTO POSITION 2 10 ...

Page 12: ...LETE ON OFF INSTALLATION IS NOW COMPLETE TURN POWER ON TO CONFIRM OPERATION TURN POWER ON WINTERIZATION 1 REMOVE LIGHT FROM NICHE 1TWIST LIGHT ASSEMBLY INCLUDING ADAPTER PLATE COUNTER CLOCK WISE TO RELEASE FROM NICHE 11 ...

Page 13: ...SSEMBLE RED TERMINAL COVER TO PLUG USING NO 2 PHILLIPS HEAD SCREWDRIVER RECOMMENDED STORE PLUG AND CABLE WITHIN NICHE DURING WINTER PERIOD 1 2 3 ASSEMBLE TERMINAL COVER TO PLUG STORE IN NICHE STORE LIGHT HEAD WITH ATTACHED ADAPTER PLATE IN A DRY AND SAFE PLACE DURING THE WINTER SEASON 3 12 ...

Page 14: ...receiver Connect the equipment into an outlet on a circuit different to that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help Do not make any changes or modifications to the equipment unless otherwise specified in the manual FCC COMPLIANCE STATEMENT ELECTRICAL GROUNDING AQUA LAMP is registered trademark of Consolidated Pool Spa Industries Inc Can...

Page 15: ......

Page 16: ...NOTE PLEASE STORE THIS MANUAL IN A SAFE PLACE FOR FUTURE REFERENCE COPYRIGHT 2020 SPA ELECTRICS PTY LTD ALL RIGHTS RESERVED CA 20211103 www spaelectrics com ...