Operation instruction MagicBox
Seite
10
von 21
5.4.1 Change brush
⚫
Unscrew the Teflon sleeve completely.
⚫
Remove the Teflon sleeve.
⚫
Loosen the brush with the help of the
spanner (SW10).
➢
To do this, insert the open-end wrench
into the wrench surface of the brush
and the adapter.
⚫
Unscrew the old brush.
⚫
Screw on a new brush.
➢
Clean the thread of electrolyte
residues with distilled water.
⚫
Now slide the Teflon sleeve over the new
brush again.
➢
Tip: moisten the brush with electrolyte
Note
Make sure that the Teflon sleeve
is not screwed onto the thread at
an angle.
⚫
Screw the Teflon sleeve onto the adapter
until the working dimension (a =
10-15mm) is reached.
➢
Please refer to chapter 4.4.2.
Note
When replacing the brush, check the O-rings of the adapter and inner part for
damage.
⚫
Only remove the adapter if the front
contact surface or the thread are charred.
⚫
Replace the damaged O-rings if
necessary.
⚫
In this case, the O-ring seals set
EP-B-0049 are needed.
O-ring seals
EP-B-0049
2x1, 6x1, 8,5x2 FKM
Adapter