enthalpy heat exchanger clean from dirts (at least once per two year)
of both control panels operation can be found in point 6.4 and 6.5.
The main functions of the unit:
6. CONTROLS
of the unit according to connected humidity sensor. Detailed description
- the unit should not work without installed G3 and F9 filters - this can lead to dirt
and clogging of the enthalpy exchanger
- the unit should be protected against the influence of frost / water
the periodic cleaning of filter and exchanger should be performed much more
often, not allowing the items to 'clog’
- before service or exchange of the device it is obligatory to cut off the current
supply
- do not limit or cover the inlet and outlet of the device
(I. e. appropriate insulation, preventing lowering the temperature in the room
below 0 ° C, pre-heater, etc.)
- the device should be kept out of reach of children and animals
- after operating time of the device, please utilize it concerning the local norms
and regulations
on technical parameters of the device and lead to loss of warranty
6.1 CHARACTERISTIC
- F9 filter should be replaced with the new one when filer alarm appears
- the unit should not be used for long-term supplying/exhausting air with relative
humidity exceeding 80%
·
unit's casing clean from dirt (at least once per year)
- it is recommended to clean the device periodically:
- do not install, service the device with wet hands or barefoot
·
G3 filter blow with compressed air to remove dirt and dust (at least once per
quarter)
- for installation of the device in a place where is high dust concentration,
-failure to comply with cleaning obligations may have a negative effect
- if the device is not used for a longer time and lead to loss of warranty disconnect
the power supply
Energy recovery unit INSPIRO series has technologically advanced controller,
which optimise the unit operation. Communication with the controller is possible
with control panel, available in two versions - STANDARD and PREMIUM.
The latter besides attractive new design and touch screen enables operation
- speed selection
– independent regulation of supply and exhaust fans airflows
in wide range (10 different speeds)
- weekly schedule
– it is possible to set a weekly work schedule of the unit
(i. e. without energy recovery) if there is no heating / cooiling demand
when the temperature of exhaust air drops below the set value
- CO
2
sensor (optional) –
if the set value of permissible CO
2
concentration
with external electrical heater to supply air at required temperature
-defrosting with return air–
the process is activated automatically
-automatic bypass
–the function allows to supply outside air directly
is exceeded, the unit automatically starts to work at its highest speed
- relative humidity sensor (optional; only for control panel PREMIUM)
-
- defrosting with preheater (optional)
– the process is activated automatically
when the temperature of exhaust air drops below the set value (see point 6.6)
if the set value of permissible relative humidity is exceeded, the unit
automatically starts to work at its highest speed
-electrical heater control (optional)–
the controller can cooperate
- defrosting with preheater (optional) – the process is activated automatically
when the temperature of exhaust air drops below the set value (see point 6.6)
- error code –
if there is an error, you can check on the panel an error code,
- data memory –
the controller "remembers" the settings in a case of power
supply break
- free cooling –
the function enables direct supply of cold outside air by activating
bypass at any time, using 'By-pass' terminals (see wiring diagram in point 7)
what making easier to diagnose the problem
- working condition monitor –
there is a possibility of signalising stats of the unit
(operation or failure) by light or sound signalisation, using 'Operation signal'
the value set at the differential pressure switch, indicating the need of filter
replacement
- filter alarm –
the alarm appears if the pressure drop on the F9 filter exceeds
(see wiring diagram in point 7)
and 'Failure signal' terminals (see wiring diagram in point 7)
- fire switch –
emergency shutdown using 'Fire alarm signal input' terminals
be made by the qualified staff, who possess the qualifications due to the domestic
and local norms, regarding electrical installations
in clogging of the exchanger and filters by fats and greases
- do not use the unit for direct exhaustion of kitchen vapors - this may result
3.1. GENERAL PRINCIPLES
- mounting elements not included in the kit, you should buy them yourself
and make sure they are suitable for this type of installation
(for INSPIRO 150 - INSPIRO 500 devices) or 450 mm
(for INSPIRO 650 - INSPIRO
1300)
- the device should be installed in a way that allows easy access to the inspection
door and the electrical box
- exemplary installation with energy recovery unit is shown in the figure below
- the device must be installed horizontally
- the minimum gap in which the device will be installed is at least 320 mm
3.
ASSEMBLY
- protect the openings of the unit against the ingress of dust during installation
- device is designed for hanging mounting
with tape or sealed in accordance with domestic or local norms
- outside ducts (i. e. fresh and exhaust air) should be thermally insulated
and carried out with a drop of 1 - 2% toward the outside in order to prevent water
entering into the unit
of the device:
- the electrical installation of the building shall have a residual current device
- connection between ducts and the openings of the device must be secured
- the energy recovery unit and ducts cannot run close of flues (e. g. form boiler)
3.2
DUCTING
- it is not allowed to make ducts in the way shown below:
- fire dampers must be installed in accordance with domestic or local fire
regulations
in accordance with domestic or local norms
- before start up ensure there are no obstructions to or in the ducts
- the device must not be exposed to an ambient temperature above 40 ° C
- operation of heater should be synchronous with the unit
4.1. CONNECTION OF THE DEIVCE TO THE ELECTRICAL SYSTEM
- the recommended cross sectional area of the supply wires is 1.5
m
m²
and the control wires 0.5
m
m²
- it is recommended to check the electric installation and controls before the first
start
- outside ducts should be ended by intake and exhaust outlets, located
- duct silencers can be used to minimize noise in the room
4. INSTALLATION INSTRUCTIONS
- all works concerning electrical installation should be made by the qualified
personnel (who possess required authorizations to install electrical equipment),
based on wiring schematic diagram
(see point 7)
5. PRECAUTIONS & WARNINGS
The precautions mentioned below must be strictly followed during operation
- all works concerning electrical installation (disassembly, repair etc.) should
Excossive bending angle
Reduce the diameter
of the junction part
Too many bending parts
Summary of Contents for INSPIRO
Page 4: ...INSPIRO 350 INSPIRO 500 INSPIRO 650 INSPIRO 800 INSPIRO 1000 INSPIRO 1300...
Page 10: ...7 CONNECTION SCHEME...
Page 12: ...Warranty card Reventon Group Sp z o o Ltd 556 Wyzwolenia Street 43 340 Kozy Poland...
Page 13: ...Reventon Group Sp z o o Ltd 556 Wyzwolenia Street 43 340 Kozy Poland www reventongroup eu...