6.1.4 SPECIAL CYCLE
In special cycles the features are:
Possible empties from 2 to 5 (default is two)
Sterilization from 5 min. to 99 min.
Dry from 10 min. to 99 min.
Temperature 121 ° or 134 °
Note: when set to manual water filling, the sterilizer automatically asks filling of clean water. Choosing SPECIAL
CYCLE: Press "START" to confirm.
SPECIAL CYCLE1
SPECIAL CYCLE2
If you decide you want to continue with the SPECIAL CYCLE 1 press "START":
SPECIAL 1
OPERATOR CODE01
PRE VACUUM 2
TEMPERATURE134
TIME STER. 05
TIMER 10
OPERATOR CODE
press START to enter and use the arrows to change the numbers
SPECIAL 1
OPERATOR CODE
01
Press “ESC” to exit.
SPECIAL 1
OPERATOR CODE 01
PRE VACUUM 2
TEMPERATURE134
TIME STER. 05
TIMER 10
PRE VACUUM
-
to confirm press “START”
SPECIAL 1
PRE VACUUM
2