19
ROUTINE MAINTENANCE
WARNING:
Improper installation, adjustment, alteration, servicing or maintenance can result in personal
injury and property damage. Always refer to this manual for normal maintenance requirements.
For further assistance or additional information consult a qualified gas installer, your REVERSO
MFG. dealer or your local gas supplier.
This appliance must not be operated if it or the gas controls have been under water. Contact a
qualified gas technician for service before attempting to operate.
This appliance should be serviced regularly, to ensure continuing safety and efficiency contact a
qualified technician at least annually.
For cleaning, turn the gas control knob (or Honeywell valve control switch) to the "OFF"
position. This will extinguish the pilot flame. Wait at least five (5) minutes before cleaning.
NOTE: This appliance is equipped with Neo Ceram Glass which can only be broken by a
significant impact or misuse.
FOR CLEANING THE INSIDE OF THE FIREBOX
Gently remove the embers and place on a piece of paper towel until ready to replace.
Remove the logs carefully from the combustion chamber and vacuum the burner compartment
thoroughly. Vacuum any dust on the logs and remove any lint from the main burner and pilot
burner.
After carefully replacing the logs and ember in their correct positions, and resealing the door,
relight the pilot following the instructions on the attached label, and turn on the main bum
1. Check to ensure that all burner ports are list and burning properly.
2. Check to ensure that the right branch of the pilot flame is engulfing the thermocouple tip,
while the left branch of the pilot flame is engulfing the thermopile and the other branch is long
enough to light the rear main burners.
3. Check to ensure that the main burner lights instantly when the on switch is turned on and that
the flame carries across to the front burner fairly evenly.