7
generate enough electricity to operate the main burner is controlled by the built-in air
flow proving switch that closes the circuit when sufficient pressure has built up for
optimum safe combustion.
The optional Honeywell gas control- provides fully automatic ignition and operation of
the appliance, controlled by a thermostat or wall switch.
The DVF200 N /P models may also have a fan delay limit switch (snapdisc) mounted in
the control compartment of the appliance. This switch is designed to delay the operation
of the air circulating fan until sufficient heat has built up, to avoid uncomfortable drafts
and to hold the air circulating fan on for several minutes after the burners have shut-off,
extracting all of the usable heat. The air circulating fan and delay switch with fan speed
control are optional.
When supplied with the optional air circulating fan, the appliance does come fully
equipped with a 120 volt household plug which will supply electrical power for the air
circulation fan.
When connected to 120 volts, the appliance must be grounded in accordance with local
codes, with the current version of CSA C22.1 (in Canada) or the National Electrical Code
ANSI/NFPA 70.
Circulation fan: 120V / 60 hz - Variable speed fan.
NOTE: Operation of the fan increases the efficiency and the heat output of the appliance.
LOCATIONS
As noted earlier, these appliances are approved for bedroom installations.
They may be installed on any flat, hard surface combustible or otherwise. They can be
located within the allowable clearances to combustibles against the wall, in a corner or
out in the center of the room if desired. (See diagram #1)
Don't forget to try to line up the center point of the flue with an open joist space above the
unit, when planning to vent vertically.