2.6 Setting Dome Camera Protocol
If a dome camera is to be installed with a keyboard controller,
select the default protocol.
Consult service personnel if a dome camera is installed with device other than a keyboard
controller.
S/W
On
Off
F
UNCTION
D1 S4-1 Enable Disable
Alarm
D2 S4-2 PAL NTSC
NTSC/PAL
D3 S4-3
Reserved
D4 S4-4
RS-422 RS-485 RS-422/RS-485
NTSC
PAL
on
S4
on
S4
D5
D6
D7
D12
P
ROTOCOL
S5-1 S5-2 S5-3 S6-4
Off Off Off Off
F2,REVO TRAX,
Pelco-D,Pelco-P:
default
Off Off On Off
F2,REVO
TRAX
Off On Off Off
Sensormatic
RS422
Off
On
On
Off
Pelco-D, Pelco-P
On Off Off Off
Vicon
On Off On Off
Ernitec
On On Off Off
Reserved
On On On Off
F2
Off Off Off On
Philips(Bosch)
Off Off On On
Reserved
Off On Off On
Dynacolor
Off On On On
Reserved
D8
D9
D10
B
AUD
R
ATE
S5-4 S6-1 S6-2
Off Off Off
2400
bps
Off Off On
4800
bps
Off
On
Off
9600 bps (Default)
Off On On
19200
bps
On Off Off
38400
bps
D11
P
ARITY
B
IT
S6-3
Off None
On Even
Figure 10 – Protocol Selection Switches
8