background image

- 1 - 

Safety and General Information 

This section contains important information regarding 
safe and efficient operation, and declarations of 
required certification / regulation compliance. Please 
read this information prior to using your Revolabs 
xTag™ wireless microphone system. 

FCC User Information 

FCC Registration Number: 0014898290 

FCC ID Number: T5V02DSKSYS Revolabs Charger 

FCC ID Number: T5V01EXEMIC Revolabs Microphone

 

FCC Notice to Users 

Users are not permitted to make changes or modify the equipment in any 
way. Changes or modifications not expressly approved by Revolabs, Inc. 
could void the user’s authority to operate the equipment.  

This device complies with Part 15 of the FCC Rules. Operation is subject 
to the following two conditions: (1) this device may not cause harmful 
interference, and (2) this device must accept any interference received, 
including interference that may cause undesired operation. 

Federal Communications Commission (FCC) 
Radiation Exposure Statement 

Important

: This equipment complies with FCC radiation exposure limits 

set forth for an uncontrolled environment. 

Industry Canada Notice to Users 

Operation is subject to the following two conditions: (1) This device may 
not cause interference and (2) This device must accept any interference, 
including interference that may cause undesired operation of the device 
Ref IC: RSS 210 Sec. 5.11. The term “IC:” before the 
certification/registration number only signifies that registration was 
performed based on a Declaration of Conformity indicating that Industry 
Canada technical specifications were met. It does not imply that Industry 
Canada approved the equipment. See Ref IC Self-Marking 6(f) and RSP-
100 Sec. 4.  

IC ID Number: 6455A-02DSKSYS Revolabs Charger 

IC ID Number: 6455A-01EXEMIC Revolabs Microphone 

 -2 - 

Restricted use with certain medical devices 

Hearing Aids 

Some devices may interfere with some hearing aids. In the event of such 
interference, you may want to consult with your hearing aid manufacturer 
to discuss alternatives.

 

Other Medical Devices 

If you use any other personal medical device, consult the manufacturer of 
your device to determine if it is adequately shielded from RF energy. Your 
physician may be able to assist you in obtaining this information.

 

Export Law Assurances 

This product is controlled under the export regulations of the United States 
of America and Canada. The Governments of the United States of 
America and Canada may restrict the exportation or re-exportation of this 
product to certain destinations.  

For further information contact the U.S. Department of Commerce or the 
Canadian Department of Foreign Affairs and International Trade. The use 
of wireless devices and their accessories may be prohibited or restricted in 
certain areas. Always obey the laws and regulations on the use of these 
products. 

02-DSKSYS North America UPCS Usage Restriction 

Due to the UPCS frequencies used, this product is licensed for operation 
only in the United States of America and Canada.  

04-DSKSYSEU European Union Usage Restriction 

Due to the frequencies used, this product is licensed for operation only in 
the European Union countries. 

Summary of Contents for xTag 02-DSKSYS-D

Page 1: ...SYS D 04 DSKSYSEU D Revolabs Inc Revolabs Inc Revolabs Inc Revolabs Inc 2007 REVOLABS INC All rights reserved No part of this document may be reproduced in any form or by any means without express wri...

Page 2: ...ection 6 Installing the xTag USB System 6 Computer Software Set up 6 Revolabs xTag Wireless Microphone 11 Using the xTag Microphone 11 Charging the Batteries 14 When to Charge 14 Setting the Broadcast...

Page 3: ...ed based on a Declaration of Conformity indicating that Industry Canada technical specifications were met It does not imply that Industry Canada approved the equipment See Ref IC Self Marking 6 f and...

Page 4: ...EU directive 2003 11 EC and EU directive 2002 95 EC 4 Introduction Introduction Introduction Introduction Congratulations on the purchase of your Revolabs xTag USB wireless microphone system This wir...

Page 5: ...one mute function 4 Mini USB connector computer audio and power connection 2 3 1 4 6 Mute Button Pressing the MUTE button toggles between muting flashing RED LED status and un muting flashing GREEN LE...

Page 6: ...em Classic settings You may notice slight differences in appearance when using other Windows operating systems To modify the default microphone earpiece audio output settings 1 At the lower right of y...

Page 7: ...d computer telephony applications e g Skype may also offer options for controlling the audio levels and playback capabilities Please consult the application guide for the software package for addition...

Page 8: ...the microphone port pointed up toward mouth 3 With the microphone in the wearing position un mute the microphone by pressing and releasing the Mute button confirm by viewing flashing GREEN LED If the...

Page 9: ...solid RED to solid GREEN as charging completes The Charger Base status indicator remains off during charging The Microphone is always muted while in the Charger Base The battery charges from fully de...

Page 10: ...the Charger Base Pairing creates an encrypted association between the Wireless Microphone and the Charger Base with a unique electronic serial number Once the Microphone and Charger Base have been pa...

Page 11: ...18 LED Status Indications LED Status Indications LED Status Indications LED Status Indications The following LED patterns are shown on either the Microphone or the Charger Base LED pattern Meaning So...

Page 12: ...0 Wireless Microphone Power proprietary 4 pin connector Audio 2 5mm mono audio Microphone pattern Unidirectional cardioid Battery Lithium Polymer up to 8 hours talk time Charge Time 2 0 hours approx R...

Reviews: