background image

 

R&D Department 

Multiuser Card 

Page  3 

 

Configuration of the Multiuser modules 

The Multiuser modules for the M51 and M100 require the 

Revox Voxnet Server

 software 

2.1.0 r6

 or higher with the 

Synology OS 

DSM 6+

. You can easily check which version is actually installed on your Voxnet Server within the Package 

Center of the Synology NAS drive. Should there be an older version installed, please update. You can find out how to do this 
in 

section

 

B

, from page 9 of this quick start manual. 

 

The integration of the M51/ M100 into the Multiuser System is carried out in the same way as the V219 Multiuser amplifiers 
via the Voxnet configurator  . The Multiuser module signs in with the identifier 

M-Card

 and can be configured within a few 

steps. 

 

 

Configuration : 

room amplifier

 

 

 

Name:  Device name for App display  

 

 

Alias: 

Name for Voxnet Text programming 

 

 

Configuration : 

source

 

 

 

Name:  Device name for App display 

 

 

Alias: 

Name for Voxnet Text programming 

 

 

Configuration : 

timer 

The Multiuser module has 4 timers (alarm clocks), which are only visible in the App. 

The 4 timers within the configurator are assigned to the Voxnet Server. 

 

Configuration :  

proxy

 

There are 3 proxies for each multiuser module available, which can be used to control external products/ devices – see 
also the 

Voxnet Configurator 

user manual for more information. 

 

 

Summary of Contents for Re: Source M51

Page 1: ...coder modules that were delivered before February 2017 must first receive an update with the M51 Programmer Tool so that they can be updated with the M Scope Bootloader tool in the installed state afterwards 5 After a successful update the following or higher software versions should be displayed Note The Revox M202 Ethernet interface is not required for the operation of the Multiuser system M100 ...

Page 2: ...r Card Page 2 Example of a wiring scheme for the Multiuser System 1 DHCP router 2 Layer 2 Switch managed 3 Synology NAS with Voxnet sw 4 Voxnet 219 amplifer with I O 5 M100 with Multiuser sub module 6 Multiuser module for M51 ...

Page 3: ...ied out in the same way as the V219 Multiuser amplifiers via the Voxnet configurator The Multiuser module signs in with the identifier M Card and can be configured within a few steps Configuration room amplifier Name Device name for App display Alias Name for Voxnet Text programming Configuration source Name Device name for App display Alias Name for Voxnet Text programming Configuration timer The...

Page 4: ...f action can be defined for certain inputa The on command is executed if independent of the cause the corresponding input is activated The off command is executed if the corresponding input was active and now has been deselected through another source being played Switching the M51 M100 off also activates the off command if previously the source input was playing Note The off command is not trigge...

Page 5: ... 4 Aux 3 Rec In Note Slot 6 is not supported by source triggers Slot 7 is reserved for the 5 1 decoder module and is also not supported The Multiuser module MUS must be installed in Slot 5 Shaded sources e g available at the tuner I O module do not change the input order Other modules sources such as the digital sources of the 5 1 decoder module are not supported in the Multiuser system Slot parti...

Page 6: ...odes into to two divisions of RC5 addresses one for purposes of the Multiuser System and one for local sources of the M51 M100 Setup Remote The last ones can be e g digital sources for the TV sound which can not be imported into the Multiuser System Regardless of whether the commands are used globally or locally they must appear in the list of the RC5 triggers of the M51 This means that even a com...

Page 7: ...peat The assigned command is carried out periodically as long as the button remains pressed release The assigned command is carried out when the button is released if it has not been held pressed for more than 2 seconds Disable Deactivates the entry e g for test purposes if you don t want to delete the entry completely Command Command line in Voxnet text new Inserts a new command line in the RC5 l...

Page 8: ...e executed can be defined The new entry can be applied with the ü icon or deleted again with The button generator can be hidden again by clicking on Normally only one code page is used per RC5 trigger Voxnet 218 RC5 codes Address Command The Code Page option for the Voxnet 218 wall mounted keypad was introduced with software version 218 2 1 00 Four different Code Pages can be selected through DIL ...

Page 9: ...source address Button Name Code Page 1 Code Page 2 Code Page 3 Code Page 4 User 1 17 63 24 63 25 63 26 63 User 2 20 63 24 55 25 55 26 55 Radio 07 63 24 56 25 56 26 56 Disc 21 63 24 57 25 57 26 57 Local input 19 63 24 51 25 51 26 51 Track_down 33 24 19 25 19 26 19 Track_up 32 24 18 25 18 26 18 Volume_down 17 24 21 25 21 26 21 Volume_up 16 24 20 25 20 26 20 Power 12 24 39 25 39 26 39 ...

Reviews: