background image

Vorfilter Maxi/Prefilter Maxi                           DORW3106               08.03.2014                       10/10 

Installation  - drivable for cars: 

Load class B (passenger car, minibus, max. axle load 2.2 To): Passenger car Complete set 
(instructions DORW2126; point 3 pictures 10, 13 and 16). Minimum distance from top of 
filter to the earth's surface: 600 mm. 

Installation  - drivable for lorries: 

SLW30 load classes D (truck max. axle load 11.5 To): Spacer ring necessary, further 
information in instructions DORW2127 as well as point 3 Pictures 10, 13 and 16. There must 
be a minimum distance of 800 mm between the top of the filter and road surface.

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 
 
 

 
 

 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 

REWATEC GmbH März 2014 

Technical changes and rights reserved. No liability for misprints 

 

The contents of the technical documentation are a component of the guarantee terms 

Planning

 

and installation regulations are to be followed, as well as the accident prevention regulations. 

Summary of Contents for Maxi

Page 1: ...Vorfilter Maxi Prefilter Maxi DORW3106 08 03 2014 1 10 Einbau und Montageanleitung Vorfilter Maxi Seite 2 5 Assembly instructions and mounting guide Prefilter Maxi Page 6 10 ...

Page 2: ...kel der für den Einbau in Verkehrsflächen der Klasse A Radfahrer Fußgänger geeignet ist Der Einbau bei höheren Verkehrslasten PKW LKW ist ebenfalls möglich Inhalt Seite 1 Einsatzbereich 3 2 Funktionsweise Anschlussvarianten Vormontage 4 3 Betrieb Wartung 4 4 Hauptabmessungen 5 5 Einbau allgemeine Hinweise 6 5 1 Einbau begehbare Version 6 5 2 Einbau befahrbare Version PKW 7 5 3 Einbau befahrbare Ve...

Page 3: ...chtung DN100 Die gewünschte Anschlussfläche ist an der Markierung auszusägen zu entgraten und dann die Dichtung einzusetzen Bei mehreren Zuläufen sind zusätzliche Lamellendichtungen erforderlich siehe Zubehör Für die gewünschte Ablaufrichtung gibt es zwei gegenüberliegende Stutzen C1 und C2 Um einen Stutzen als Ablaufleitung nutzen zu können muss er etwa 10 mm vor dem Ende abgesägt werden es kann ...

Page 4: ...rlängerung ist in einem Bereich von 70mm durch schieben stufenlos höhenverstellbar und darüber hinaus durch absägen kürzbar oder durch stapeln verlängerbar so dass sich beliebige Einbautiefen bis maximal zulässig 1 5 m realisieren lassen Filtergehäuse Filtergehäuse mit Rohrverlängerung ...

Page 5: ... ä 3 Einsetzen und ausrichten des Filters Rohrverbindungen anschließen 4 Verfüllen mit Verfüllmaterial in etwa 100mm dicken Lagen Die Dicke des Verfüllmaterials um das Filtergehäuse sollte ca 100 mm betragen Der Rest der Lage kann mit Aushub verfüllt werden Die Lagen sind einzeln zu verdichten z B mit 15 Kg Handstampfer Kantholz o ä ohne Maschineneinsatz Diese Art der Verfüllung sollte bis etwa 10...

Page 6: ...able for the installation in public thoroughfares of the class A cyclist pedestrian The installation in areas with higher traffic loads passenger car truck is also possible Contents Side 1 Application Area 6 2 Operating mode connection possibilities pre mounting 7 3 Operation servicing 7 4 Main dimensions 8 5 Installation general notes 9 5 1 Installation walkable version 9 5 2 Installation version...

Page 7: ... fits The chosen connection point needs to be sawn of and smoothed as marked on the filter then the gasket is fitted With several inflows additional lamella gaskets are necessary see accessories For the desired outflow direction there are two opposite openings C1 and C2 To be able to use an opening as an outflow pipe it must be sawn off about 10 mms before the end then a sleeve DN 100 can be put o...

Page 8: ...06 08 03 2014 8 10 4 Main dimensions The pipe extension is height adjustable by pushing up 70 mms at a time or to shorten it can be sawn off to size The maximum installation depth allowed 1 5 m Filter body Filter body with pipe extension ...

Page 9: ... the inflow pipe to the filter With nonobservance the filter overflows with heavy rainfall This also applies to the outflow pipe 5 1 Installation walkable version Workflow of the installation 1 Excavation of the pit 2 Fill with about 100 mm thick bedding of filling material compact it well machine or three operations with hand tamper 15 kg squared timber or similar 3 Insert and adjust the filter j...

Page 10: ... SLW30 load classes D truck max axle load 11 5 To Spacer ring necessary further information in instructions DORW2127 as well as point 3 Pictures 10 13 and 16 There must be a minimum distance of 800 mm between the top of the filter and road surface REWATEC GmbH März 2014 Technical changes and rights reserved No liability for misprints The contents of the technical documentation are a component of t...