3
MASS FILTER
INSTRUCTIONS
The manual can be downloaded as a PDF file from the website: www.rexnordic.uk
Read this manual carefully and keep it in a safe place for future reference.
This manual covers the filtration unit that is described (name and reference) in the attached document “TECHNICAL CARACTER-
ISTICS”. All electrical installations should comply with the following standard:
European Low Voltage Directive 2014/35/CE.
EN 60335-2-41, safety of household or similar electrical appliances,
particular requirements for pumps.
The installation must therefore comply with all rules pertaining to “the construction of electrical installations within specific
confines: swimming pools and fountains, or the equivalent standard in force in each region or country. The electrical installa-
tion should be done by someone qualified in working with electrical equipment. This unit is not designed for anyone with a
physical, sensory or mental handicap or people lacking in experience, unless done under supervision or with instructions of
use from a person in charge of safety.
•
The height of the sand should not exceed 2/3 of the height of the tank.
•
It is important to check that the suction ports are not blocked.
•
Check the level of dirt in the filter regularly.
•
The unit must not be switched on while the pool is being used.
•
Do not operate the unit unless it is properly primed.
•
NEVER touch the filter when it is operating if you are wet or have wet hands.
•
When handling the filter or valve, DISCONNECT the power supply.
•
Make sure that the ground is dry before touching the electrical equipment.
•
Do not submerge the or put it in a place where it could be submerged.
•
Do not permit children or adults to sit or lean on the unit. Children should be supervised to ensure that they do no play
with the unit.
•
If the power cord is damaged, it must be replaced by the manufacturer or an approved service engineer or a similarly quali-
fied person in order to avoid hazards.
•
It is essential that any damaged component or set of component is changed as soon as possible. Only use parts that are
approved by the sales representative.
•
The unit should be connected to a power supply (see data on the pump’s plate), with an earth connection, protected by
a residual current device (RCD) with a rated residual operating current that does not exceed 30 mA. or by an insulating
transformer.
•
Forbid access to the pool if any damage of the filtration system(s) occurs.
•
Whenever chemical products are used to treat the pool water, it is recommended that the minimum filtration time is re-
spected in order to protect bathers’ health, as stated by the health regulations.
1. PACKAGING COMPONENTS
This unit is designed for above-ground pools.
UNITS COMPONENTS
1
Base
1
Blow-molded filter housing
1
Pump
1
Valve
1
Set of straps
1
Pressure gage
1
A Ø38 mm valve-pump connection hose (metal clamps
included)
Summary of Contents for Mass Filter
Page 1: ...INSTALLATION AND MAINTENANCE MANUAL REXENER Mass Filter ...
Page 10: ...10 1 Ø300 mm Images of the products are exemplary 2 Ø300 mm ...
Page 11: ...11 3 Ø300 mm 4 Ø300 mm RETURN PUMP ...
Page 12: ...12 5 Ø300 mm Installing the pressure gauge 6 Ø300 mm Installing the pump hose ...