Demounting and replacement 59/76
CytroPac, RE 51055-B/02.2021,
Bosch Rexroth AG
12 Demounting and replacement
Only remove device parts to the extent required to carry out the necessary work.
In general, all disassembled parts should be reassembled properly at the intended
position.
12.1 Preparing demounting
▶
Ensure sufficient stability of the hydraulic power unit.
▶
Observe the weight and the position of the center of gravity of the hydraulic
power unit.
▶
Do not loosen the fixation of the hydraulic power unit before the stability of the
machine is ensured by other means.
▶
Prior to demounting, drain the hydraulic fluid from the hydraulic power unit as
described in chapter 11 “Decommissioning”
▶
Use the intended eyebolt, see Fig. 5.
▶
Check secure fitting of the eyebolt if the hydraulic power unit is to be transported
after demounting.
▶
Please note that the hydraulic power unit may be mounted on an optional
mounting plate, see Fig. 15.
▶
To remove the hydraulic power unit from the mounting plate, loosen the screw,
see Fig. 13.
Safety measures:
▶
Always observe applicable instructions for the overall machine/system.
▶
Unless these instructions provide different information, proceed as follows:
– Carry out decommissioning as described in chapter 11 of these operating
instructions.
– Unauthorized personnel must not be allowed access to the working area.
12.2 Demounting
▶
For demounting, carry out the work steps described in chapter 7 “Mounting" in
reverse order.
▶
Hydraulic fluid will run out of the hydraulic line system of the hydraulic power
unit or hydraulic system even after previous draining. For this reason, close all
outlets of lines with suitable blanking plugs.
After demounting, observe the information on safe transport of the product in
chapter 6 "Transport and storage".