Labeling at the housing Connection type
Connection type (at the
device)
Mating connector or
cable (from outside)
XDP
Connection for external
monitor
Display port socket,
(20-pin)
Display port plug,
(20-pin)
XAOI
Connection for external
audio
3.5 mm jack socket
3.5 mm jack plug
XDI+tx
Connection for a remote
operating display
Optional
RJ45 socket, 8-pin
RJ45 plug
(twisted pair, 8-wire)
Tab. 9-1: Interfaces
Malfunctions due to insufficient shielding!
NOTICE
Use only shielded cables and metallic or conductive connector/coupling covers
with large-area shield support.
9.2 PC voltage supply X1S1
The 24 V DC voltage supply for the control cabinet PC is connected via the
"X1S1" connection.
1 2 3
Fig. 9-3: Interface for 24 V voltage supply
Pin
Function
①
+24 V supply voltage
②
0 V supply voltage
③
Functional earth
Tab. 9-2:
9.3 USB interfaces XUSB1 to XUSB4
The devices are provided with four USB interfaces on the connector panel
(XUSB1/2: USB 3.0, XUSB3/4: USB 2.0).
IndraControl PR31 and VR31 Control
cabinet PC and panel PC
15/53
Interfaces
R911397433_Edition 02 Bosch Rexroth AG