Errors
Correction
No image visible
●
Connect the supply voltage and check the X1S1
connection
●
Connect the display port or CDI+ cables correctly
●
If panels with a display port are used, use only Bosch
Rexroth display cables to connect the panels, refer to
chapter 5.6 "Connecting cables of the display port" on
.
●
Use only active DVI and HDMI display port adapters.
When using simple passive adapters, no image is
displayed at the DVI or HDMI monitor.
Distorted display due to incorrect
display resolution
●
Set the correct display resolution in the graphics driver.
The standard resolution of the Windows images (also for
the recovery sticks) is FullHD (1920×1080). Set the
correct value once if displays with a smaller resolution are
used
●
Restart the control cabinet PC
Tab. 13-1: Error causes and troubleshooting
14 Maintenance
Only the maintenance works at the device listed in this chapter are
permitted.
For further information in the event of repair, please contact the
Bosch Rexroth Service.
Loss of IP degree of protection due to incorrect
maintenance.
NOTICE
Ensure that the IP degree of protection remains during maintenance!
14.1 Cleaning notes
Dissolving front glass sealing with solvent!
NOTICE
●
Do not use solvents
●
Do not use high pressure cleaning device
IndraControl PR31 and VR31 Control
cabinet PC and panel PC
43/53
Maintenance
R911397433_Edition 02 Bosch Rexroth AG