Converter
Mains chokes
Mains filter
Explanation
HCS03.1E-
W0100
HNK01.1A-A075-E0080
Standard combination for 1 converter
Motor cable length ≤ 75 m
HNL01.1E-0362-
N0080
-
Standard for operating one drive controller without mains filter
HNL01.1E-0362-
N0080
NFD03.1-480-075 Combination for 1 converter
Motor cable length ≤ 5 m
HNL01.1E-0362-
N0080
HNF01.1A-F240-
E0125
Central supply to axis systems
●
Type current HMS ≤ W0070
●
Type current HMD ≤ W0036
●
Sum of type currents ≤ 270
●
2 × 330 nF ≤ C
y
≤ 2 × 600 nF
●
Motor cable length ≤ 240 m (f
s
= 8 kHz)
HNL01.1E-0362-
N0080
HNF01.1A-M900-
E0125
Central supply to axis systems
●
Type current HMS ≤ W0070
●
Type current HMD ≤ W0036
●
Sum of type currents ≤ 270
●
2 × 330 nF ≤ C
y
≤ 2 × 1225 nF
●
Motor cable length ≤ 900 m (f
s
= 8 kHz)
HNL01.1E-0362-
N0080 with
HNL01.1E-2800-
S0125
Customer-side
Standard mains choke connected in series with current-com‐
pensated mains choke to reduce line-frequency leakage cur‐
rents
Bosch Rexroth AG
DOK-INDRV*-SYSTEM*****-PR06-EN-P
Rexroth IndraDrive Drive Systems with HMV01/02 HMS01/02, HMD01, HCS02/03
118/309
Configuring the Drive System