UL ratings
For using the component in the scope of CSA / UL, take the UL
ratings of the individual components into account.
In the scope of CSA / UL, it is exclusively the following compo‐
nents which have been approved to supply the components HMS,
HMD, KCU, KSM, KMS:
●
HMV01.1E
●
HMV01.1R
●
HMV02.1R
●
HCS02.1E
●
HCS03.1E
Make sure that the indicated short circuit current rating SCCR is
not exceeded, e.g. by appropriate fuses in the mains supply of the
supply unit.
Wiring material UL
In the scope of CSA / UL, use copper 60/75 °C only; class 1 or
equivalent only.
Allowed pollution degree
Comply with the allowed pollution degree of the components (see
"Ambient and Operating Conditions").
C-UR-US Listing
The motors are listed by UL ("Underwriters Laboratories Inc.®"). You can find
the evidence of certification on the Internet under
under
"Certifications" by entering the file number or the "Company Name: Rexroth".
●
UL standard: UL 1004-1
●
CSA standard: Canadian National
Standard C22.2 No. 100
Company Name
BOSCH REXROTH ELECTRIC DRIVES &
CONTROLS GMBH
Category Name:
Servo and Stepper Motors - Component
File numbers
MSK, MSM motors: E335445
Tab.5-3:
C-UR Listing
Wiring material UL (ready-made cables by Rexroth)
In the scope of CSA / UL, use copper 60/75 °C only; class 6 or
equivalent only.
Allowed pollution degree
Comply with the allowed pollution degree of the components (see
"Ambient and Operating Conditions").
Bosch Rexroth AG
DOK-INDRV*-SYSTEM*****-PR06-EN-P
Rexroth IndraDrive Drive Systems with HMV01/02 HMS01/02, HMD01, HCS02/03
56/309